Laserfiche WebLink
C5. Fiberglas° Reservoir 9wnsor I Electrical <br /> After filling with liquid,the level in the Fiberglas reservoir maybe All electrical connections must be in accordance with local codes.To wire <br /> monitored periodically by using a dipstick or continuously by using the the reservoir sensor to the control panel use 16 AWG or 14 AWG.type <br /> optional reservoir sensor,m conjunction with an optional electronic con- THHN or M TW(contractor supplied).Wiring must be placed in water <br /> trot panel. tight conduit and junction boxes.Sensor wiring(intrinsically safe)must <br /> l The monitoring sensor is placed into the Fiberglas reservoir through a 4" not be placed in the same conduit as non-intrinsically safe wiring. <br /> diameter riser pipe from grade.The sensor includes the riser pipe cap <br /> witha 16"length of flexible conduit,which isconnectedtoaNEMA4or C7. Testing <br /> NEMA 6 electrical junction box(contractor supplied). g <br /> The PVC riser pipe cap isdesigned to slipon and off the PVC fitting install- Remove the sensor from the Fiberglas reservoir to simulate a low liquid <br /> ad on the top of the riser pipe.These pipe fitting connections are designed level condition;removing the sensor from the fluid in the reservoir will <br /> to provide quick and easy access to the sensor and reservoir without activate the control panel low level alarm.Then,immerse the sensor into <br /> disconnecting any electrical or piping connections.However,for bucket of water to activate the high level alarm. <br /> extreme high groundwater conditions,to prevent the intruslon of <br /> groundwater into the reservoir,the factory drilled vent holes(4)in �+ <br /> the PVC riser pi pe cap must be plugged and a separate vent line C8, Reservoir Leak Detection <br /> installed from the riser pipe to above ground.In addition,the PVC <br /> riser pipe top should be glued to the riser pipe fitting. In the event of an alarm condition,remove the riser pipe cap and extract <br /> the reservoir sensor.Then use a dipstick to measure the reservoir liquid <br /> level to determine if the low or high level alarm was tripped.If the dipstick <br /> measurement is 1.25"(2.00"for tanks 15,000 gallon capacity or larger) <br /> Reservoir Se <br /> nsoror tens,the reservoir has drained,indicating a low level alarm.If the <br /> Model Rsloexbladorla:t dipstick measurement is 14"or higher,the high level alarm was <br /> activated. <br /> leadFor a low level alarm,refill the reservoir to 2A full and continue monitoring. <br /> For a high level alarm,remove liquid from the reservoir until it is 2A full and <br /> continue monitoring. <br /> If an alarm condition occurs and the reservoir level is normal,the control <br /> VMbolas panel is improper)yy wired(consult your local electrician)or has a defec- <br /> r pipe five component.(See Section D9 on Control Panel False Alarms.) <br /> �� If an additional low level or high level alarm occurs,call the O/C Tanks <br /> pipe Field Service Manager at 419-248-8196. <br /> �.�� lartlelar Fiberglas+Reservoir Installation Detail For <br /> )eel lQuidSwitcid�atable Extreme High Water CorMitiomead cable <br /> t'. r � Traffic <br /> _S Pad . R.ro w{ ^%B�y,•,_� ,; <br /> "ate' <br /> _J \ NEEMA6 <br /> Jurlolion Box <br /> Pescvvpir_ dried holets <br /> Fiberglas"Reservoir Nominal Installation Detail w"to grade <br /> ==:T= = <br /> OV��_sp-4� f, '.)4 C i,i.Bi:r.ad'_-��,-,�`,qi-.,b 'aa'f^wS.�:sv e4 FRP <br /> V dap ng Junction Corbu6"pe.- box" tppomrol pantyHNeme<) (watertight) Doible vat Mrker High lee)alarmr lav letel alarm" FRP..-.:: RSeIVC!=C] GJ p p p G <br /> "contracts supplied;use NEMA 6 <br /> For high grWM atercordmons <br /> 9 <br />