My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2004 - 2007
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PESCADERO
>
1535
>
2300 - Underground Storage Tank Program
>
PR0232495
>
COMPLIANCE INFO 2004 - 2007
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
12/28/2023 1:44:43 PM
Creation date
11/8/2018 9:52:14 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2004 - 2007
RECORD_ID
PR0232495
PE
2361
FACILITY_ID
FA0003854
FACILITY_NAME
YRC INC
STREET_NUMBER
1535
Direction
E
STREET_NAME
PESCADERO
STREET_TYPE
Ave
City
Tracy
Zip
95304
APN
21306026
CURRENT_STATUS
01
SITE_LOCATION
1535 E Pescadero Ave
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\P\PESCADERO\1535\PR0232495\COMPLIANCE INFO 2004 - 2007.PDF
QuestysFileName
COMPLIANCE INFO 2004 - 2007
QuestysRecordDate
12/6/2016 12:58:59 AM
QuestysRecordID
3271591
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
339
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITOF"NG SYSTEM CERTIFt" ATION <br /> This form must be used to document testing a~servicing of monitoring equipment. Technicia�fiaL, prepare a separate certification or <br /> report for each monitoring system control panel. A copy of this form must be provided to the tank system owner/operator. The <br /> owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> General Information SET Job#: 019238 <br /> Facility Name: _ _ Yellow Transportation TCY Bldg.No.: <br /> Site Address: 1535 E.Pescadero Ave. City:_ Tracy State: CA Zip: 95376 <br /> Facility Contact Person:___ Richard Smith Contact Phone No.: 209-833-1300 <br /> Make/Model of Monitoring System: Veeder Root TLS 25013:2 Date of Testing/Servicing: 3/18/2004 <br /> Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate a ui ment inspected and/or serviced: <br /> Tank ID: TCY5 Gear Oil 6K Tank ID: TCY6 Antifreeze 61K <br /> ®In-Tank Gauging Probe. Model: Mau 1 N In-Tank Gauging Probe. Model: _ _ Mag 1 <br /> ®Annular Space or Vault Sensor. Model: 407 ®Annular Space or Vault Sensor. Model: 302 <br /> ®Piping Sump/Trench Sensor(s). Model: _ 208 _ ®Piping Sump/Trench Sensor(s). Model: _ 206 <br /> []Fill Sump Sensor(s). Model: ❑Fill Sump Sensor(s). Model: <br /> ❑Mechanical Line Leak Detector. Model Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. Model: <br /> ®Tank Overfill/High-Level Sensor. Model: OPW 6150 ®Tank Overfill/High-Level Sensor. Model: oPW 6150 <br /> El Other ❑Other <br /> Tank ID: TCY7 Waste Oil 4K Tank ID: TCYSA <br /> N In-Tank Gauging Probe. Model Mag 1 ❑In-Tank Gauging Probe. Mo �� ��p-�I� �� <br /> NAnnular Space or Vault Sensor. Model: . 302 _ ❑Annular Space or Vault Sensor. Moe �w <br /> IN Piping Sump/Trench Sensor(s). Model: _ 208 ❑Piping Sump/Trench Sensor(s). Model: <br /> ❑Fill Sump Sensor(s). Model: _ _ --__ ❑Fill Sump Sensor(s). Model: R0 5 2004 <br /> ❑Mechanical Line Leak Detector. Model: ❑Mechanical Line Leak Detector. Model: <br /> ❑Electronic Line Leak Detector. Model: ❑Electronic Line Leak Detector. MoCel tONN E TFfEAUH <br /> NTank Overfill/High-Level Sensor. Model: 0121011111151) ❑Tank Overfill/High-Level Sensor. ModelPEKMI I/SEHVIULS- <br /> ❑Other ❑Other <br /> Dispenser ID: Dispenser ID: <br /> ❑Dispenser Containment Sensor(s). Model: - ❑ Dispenser Containment Sensor(s). Model: <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dis enser Containment Float(s)and Chain(s). ❑ Dispenser Containment Floats and Chain(s). <br /> Dispenser ID: Dispenser ID: -- <br /> ❑Dispenser Containment Sensor(s). Model: _ ❑ Dispenser Containment Sensor(s). Model <br /> ❑ Shear Valve(s). ❑ Shear Valve(s). <br /> ❑ Dispenser Containment Floats and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: Dispenser ID: <br /> ❑ Dispenser Containment Sensor(s). Model: ❑ Dispenser Containment Sensor(s). Model: <br /> ❑Shear Valve(s). ❑ Shear Valve(s). <br /> ❑Dispenser Containment Floats and Chain(s). ❑ Dispenser Containment Float(s)and Chain(s). <br /> Include information for every tank and dispenser at the facility. <br /> Certification-t certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' guidelines. Attached to <br /> this Certification is information (e.g. manufacturers' checklists) necessary to verify that this information is correct and a Plot Plan showing the layout of <br /> monitoring equipment. For any equipment capable of generating such reports,i have also attached a copy of the report.(Check all that apply): <br /> N System set-up ® Alarm history <br /> Technician Name(print): Roy Walker Signature: /� _ <br /> Certification No.: 4307 License.No.: 814027 <br /> Testing Company Name: Shirley Environmental Testing Phone No.: (626)444-7447 <br /> Site Address: 1928 Tyler Avenue Suite K South EI Monte,CA 91733 Date of Testing/Servicing. 3/18/2004 - <br /> Monitoring System Certification Page I of 4 3101 <br />
The URL can be used to link to this page
Your browser does not support the video tag.