My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1986-1997
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PINE
>
1126
>
2300 - Underground Storage Tank Program
>
PR0231364
>
COMPLIANCE INFO 1986-1997
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
4/1/2020 11:59:16 AM
Creation date
11/8/2018 9:53:01 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1986-1997
RECORD_ID
PR0231364
PE
2361
FACILITY_ID
FA0003771
FACILITY_NAME
E F KLUDT & SONS INC
STREET_NUMBER
1126
Direction
E
STREET_NAME
PINE
STREET_TYPE
ST
City
LODI
Zip
95240
APN
04906022
CURRENT_STATUS
01
SITE_LOCATION
1126 E PINE ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\P\PINE\1126\PR0231364\COMPLIANCE INFO 1986-1997.PDF
QuestysFileName
COMPLIANCE INFO 1986-1997
QuestysRecordDate
9/7/2017 7:10:04 PM
QuestysRecordID
3628042
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
273
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
OPTION 2A <br /> ARTICLE 3, SECTION 2633/2634 <br /> MOTOR VEHICLE FUELS ONLY <br /> CONS!K1 GTION <br /> 1 . Requirements: <br /> A. Approved tank construction material <br /> B. Leak interception and detection system which complies with Article 3, <br /> Section 2631 (c). <br /> C. Membrane liners must comply with Article 3, Section 2633(e) , (1 ) , (2) , <br /> (3) , (4) , ( 5) and are only allowed for piping systems (Department Policy) <br /> D. Demonstrate that the leak interception and detection systems protects <br /> round water from contamination (Article 3, Section 2633(f) , (1 ) , (2) , (3) , <br /> round(5) . (6) , (7) . <br /> E. Pressurized piping systems must be installed with a leak detector that is <br /> capable of automatically shutting off the product pumps. <br /> 1 . Any single wall component "tank or piping" requires daily inventory <br /> reconcilliation and annual precision tests as part of the monitoring <br /> program. <br /> F. Before covering, the tank(s) and system(s) must be tested to NFPA 30, <br /> Standards. <br /> G. Before use - the tank(s) and system(s) must be tested in accordance to <br /> NFPA 329. <br /> H. Provide soil profile of vadose zone if membrane liners are used. <br /> OPTION 2B <br /> ARTICLE 3, SECTION 2634 <br /> MOTOR VEHICLE FUELS ONLY <br /> MONITORING <br /> I . Requirements (leak interception and detection system(s)). <br /> A. Floor must be constructed on a firm base and sloped to a collection sump. <br /> B. Access casings must be installed in accordance to Article 3, Section <br /> 2634 (c) (1 thru 6) , (d) (1 ). <br /> C. Submit written monitoring and response plan as stated in Article 3, <br /> Section 2634 (d) (1-3), 2634(e) (1-5). <br /> D. Hard wiring of electronic monitoring systems is required. <br /> E. Provide manufacturer's written installation instructions. <br />
The URL can be used to link to this page
Your browser does not support the video tag.