Laserfiche WebLink
R-M-S PROFESSIONAL CONSULTAA, INC. <br /> CORROSION CONTROL DEPARTMENT <br /> STOCKTON,CA 95204-(209)4663035 <br /> PROJECT: <br /> DATE: <br /> Kludt& Sons Petroleum Products 3/25/97 <br /> ADDRESS: TEST ENGINEER: <br /> 1126 E. Pine Street L. Snyder <br /> Lodi, CA 95240 <br /> EQUIPMENT <br /> POTENTIAL METER&SCALE A.W.SPERRY DM-8010 0-2VDC RECTIFIER NO. 1 <br /> VOLT METER&SCALE A.W.SPERRY DM-80100-20VDC RECTIFIER MAKE WEST <br /> AMMETER&SCALE AMPROBE O-BA RECTIFIER MODEL WSTSA-2412M <br /> WATTMETER&SCALE RECTIFIER SERIAL NO. 90FOO <br /> RECTIFIER CONDITION <br /> WIRING CONNECTIONS X GOOD BAD CORRECTED NEEDS CORRECTION <br /> PANEL COMPONENTS X GOOD BAD CORRECTED NEEDS CORRECTION <br /> DOORS X GOOD BAD CORRECTED NEEDS CORRECTION <br /> LATCHES X GOOD BAD CORRECTED NEEDS CORRECTION <br /> HINGES X GOOD BAD CORRECTED NEEDS CORRECTION <br /> PAINT X GOOD BAD CORRECTED NEEDS CORRECTION <br /> SCREEN X GOOD CLOGGED CORRECTED NEEDS CORRECTION <br /> TEMPERATURE OF PLATES X EVEN UNEVEN CORRECTED NEEDS CORRECTION <br /> TEMPERATURE OF CONTACTS X COOL HOT CORRECTED NEEDS CORRECTION <br /> INSTRUMENT READINGS <br /> DESCRIPTION Dc <br /> VOLTS DC AMPS NOTES <br /> TEST METER READINGS 11.8 0.63 2.1MV READ ACROSS SHUNT <br /> AC AC AMPS <br /> VOLTS <br /> TEST METER READINGS 121.7 0.5 <br /> DC <br /> VOLTS <br /> DC AMPS <br /> RECTIFIER METER READINGS THIS INSPECTION 11.5 0.63 <br /> RECTIFIER METER READING LAST INSPECTION 12 1.54 <br /> COARSE FINE <br /> TAP SETTING FROM PRIOR PERIOD B 4 <br /> ADJUSTED TAP SETTINGS B 4 <br /> RECTIFIER HAS A 5DAV-15A SHUNT <br /> CATH-1.XLS page 1 <br />