My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013-2016
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PINE
>
1126
>
2300 - Underground Storage Tank Program
>
PR0231364
>
COMPLIANCE INFO 2013-2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/14/2024 1:27:20 PM
Creation date
11/8/2018 9:53:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2016
RECORD_ID
PR0231364
PE
2361
FACILITY_ID
FA0003771
FACILITY_NAME
E F KLUDT & SONS INC
STREET_NUMBER
1126
Direction
E
STREET_NAME
PINE
STREET_TYPE
ST
City
LODI
Zip
95240
APN
04906022
CURRENT_STATUS
01
SITE_LOCATION
1126 E PINE ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\P\PINE\1126\PR0231364\COMPLIANCE INFO 2013-2016.PDF
QuestysFileName
COMPLIANCE INFO 2013-2016
QuestysRecordDate
9/7/2017 11:31:40 PM
QuestysRecordID
3629872
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
190
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 <br /> SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209)468-3420 Fax.,(209)468-3433 Web:www.sigov.oro/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Facty E F Kludt & Sons, Inc. Facility 1126 E. Pine, Lodi Date:Inspection Apr 1, 2014 <br /> Name: Address: <br /> VIOLATIONS <br /> # C7 C2 M Code Section HSC=CA Health and Safe Code:CFR=Code of Federal Regulations <br /> C1 =Class 1 violation',C2=Class 2 violation',M=Minor violation <br /> Non-Pressurized Piping(continued) <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1, 1984) (Mi) <br /> 703 1 1 CCR 2643(d) I Triennial line test for conventional suction piping not performed(pre-January 1, 1984) (Mi) <br /> Other Violations <br /> 999 Other: See attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> This is a Routine UST inspection and UST Monitoring System Certification inspection. The following is a <br /> Minor Violations - Notice to Comply: 104, and Class II Repeat violations: 313, 314 <br /> 104. Current financial responsibility documents have not been submitted to the EHD, in spite of the <br /> statement in the CERS website that the documents have been provided to EHD. Current financial <br /> responsibility documents are required to be submitted annually. Immediately submit a copy of the <br /> financial responsibility documents to the EHD. Alternatively, log into CERS, upload the required <br /> information, and submit for review by the EHD. Received a copy of the current documents on site; <br /> Violation was corrected on site. <br /> 313 (Repeat). The direct-bury spill container of the main red-dye diesel UST was not tested. All spill <br /> containers shall have a minimum capacity of five gallons and be capable of containing a spill or overfill <br /> until it is detected or cleaned up. Immediately discontinue deposition of petroleum into this tank until the <br /> component is repaired or replaced by a properly licensed, trained, and certified contractor under permit <br /> and inspection of the EHD. If the spill container can't be replaced immediately, there is a possibility that <br /> the UST system may be red tagged to prevent fuel inputs. (See 314 below) <br /> 314 (Repeat). Based on interview with technician and consistent with what EHD had observed during <br /> the previous MSC inspection on 4/4/2013, the drop tube with the mechanical flapper used as the overfill <br /> prevention system is missing from the main red-dye diesel UST. Immediately discontinue deposition of <br /> petroleum into this tank until the component is repaired or replaced by a properly licensed, trained, and <br /> certified contractor under permit and inspection of the EHD. If the failed component can't be replaced <br /> immediately, there is a possibility that the UST system may be red tagged to prevent fuel inputs. The <br /> main red-dye diesel UST currently receives fuel only through the syphon connection to the adjacent <br /> auxiliary red-dye diesel tank. If you wish to discontinue use of this fill port and spill container, submit a <br /> proposal in writing to EHD by 5/3/2014 how the spill container is decommissioned and locked to prevent <br /> possibility of any fuel input, and update the Monitoring Plan in CERS to reflect this change. <br /> Note: EHD reported the above spill container was once capped off and drop tube removed on 4/6/2011 <br /> but anew spill container was reinstalled in 2012. Submit Return to Compliance document by 5/3/2014 <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS F CI ITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Inspector Received By: TRIe'. <br /> C-er.� „MRj <br /> EHD 23-VRev 0 / Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.