My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2013-2016
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
P
>
PINE
>
1126
>
2300 - Underground Storage Tank Program
>
PR0231364
>
COMPLIANCE INFO 2013-2016
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/14/2024 1:27:20 PM
Creation date
11/8/2018 9:53:09 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2016
RECORD_ID
PR0231364
PE
2361
FACILITY_ID
FA0003771
FACILITY_NAME
E F KLUDT & SONS INC
STREET_NUMBER
1126
Direction
E
STREET_NAME
PINE
STREET_TYPE
ST
City
LODI
Zip
95240
APN
04906022
CURRENT_STATUS
01
SITE_LOCATION
1126 E PINE ST
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\P\PINE\1126\PR0231364\COMPLIANCE INFO 2013-2016.PDF
QuestysFileName
COMPLIANCE INFO 2013-2016
QuestysRecordDate
9/7/2017 11:31:40 PM
QuestysRecordID
3629872
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
190
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209) 468-3433 Web:www.sioov.orD/ehd <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Faallty E.F. Kludt& Sons Inc. Faal4y 1126 E. Pine St. Lodi, CA 95240 Inapeclion Apr 4, 2013 <br /> Name: Address: p <br /> Date: <br /> ! VIOLATIONS <br /> # C7 I C2 I M I Code Section HSC=CA Health and Safety Code;CFR=Code of Federal Regulahons <br /> C1=Class 1 violation'C2=Class 2 violabon;M=Minor violation <br /> Non-Preasurizad`Piping(continued) <br /> 702 CCR 2fi43(e) Biennial tightness test of gravity piping not pertormed(pre-January 1,1984) (M1) <br /> 703 CCR 2643(d) Triennial line test for conventional suction piping not performed(pre-January 1,1984) (Mi) <br /> -Other violations <br /> 999 1 1 Other. See attached"Continuation-Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II or MINOR-Notice to Comply) <br /> On site to conduct a routine inspection and witness the annual monitoring system certification testing. <br /> 204. The designated operator failed to check and note the correct test dates for the secondary <br /> containment test on the May 2012 through April 2013 designated operator monthly inspection reports. <br /> The test date was listed as October 21, 2011, but should have been listed as October 12, 2011. The <br /> designated operator failed to check and note the correct test dates for the cathodic protection test on the <br /> January 2013 through April 2013 designated operator monthly inspection reports. The test date was <br /> listed as June 11, 2012, but should have been listed as May 11, 2012. During the monthly inspection, <br /> the designated operator shall check that all required testing and maintenance for the UST system have <br /> been completed and document the dates they were done. Ensure that designated operator performing <br /> monthly ' spections at this facilityare including all of the required information on the reports. <br /> V`�s ` *�c �IN <br /> 303. The main red dye diesel turbine sump sensor was at the bottom of the sump approximately five <br /> inches away from the lowest point of the sump, part way up the sump saddle, and not located to detect a <br /> leak at the earliest opportunity. Monitoring equipment shall be maintained to be able to detect a leak at <br /> the earliest possible opportunity. Take the necessary precautions to ensure that all sensors are located <br /> at the lowest point to detect a leek at the earliest opportunity. MO✓�I Y`���c�J `T o � <br /> 314. The drop tube with mechanical flapper set at 95% for the overfill prevention system is missing from <br /> the riser of the red dye diesel main UST. Immediately discontinue deposition of petroleum into this tank <br /> until the component is repaired or replaced by a properly licensed, trained, and certified contractor under <br /> permit and inspection of the EHD. If the failed component can't be replaced immediately, there is a <br /> possibility that the red dye diesel main UST system may be red tagged to prevent fuel inputs. <br /> Note: The swivel adapter from the red dye diesel main tank riser was switched to the red dye diesel <br /> siphon tank riser. The removed swivel adapter was replaced with a four inch cap to prevent filling of the <br /> red dye diesel main tank riser. <br /> Complete and submit a copy of the Return to Compliance Certification form with a statement of how <br /> each violation was corrected, including supporting documentation, by May 4, 2013. <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING To COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> Inspetlnr Recai BY: Title: <br /> EHD 23-02 Rev 04/19/12 Pape 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.