SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton, California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.siaov.org/ehd/unibii.html <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> CONTINUED <br /> Facility add as: Inspection Dare: <br /> System Transport Inc 707 East Roth Road, French Camp May 24, 2011 <br /> VIO# Code Section HSC=CA Health&Safe Code CCR=CAC de oflRegulations;V=Violation RV=Re eat Violation V V <br /> Designated operator monthly inspection:(c)(1)alarms not documented;(c)(2-4)spill containers, <br /> 23c CCR 2715(c),(e) UDCS,and sumps(if necessary)not inspected; (c)(5)required test dates not checked or noted;(c)(6) <br /> employee training not verified; (e)monthly inspection reports not maintained on site for at least 12 <br /> months <br /> 23d CCR 2715(f) Designated operator employee training:(1)not performed; (2)not current for at least one employee X <br /> on site 3 log not kept <br /> Monitoring equipment certification: (a)not performed annually; (d)test report not submitted within 30 <br /> 24 CCR.2638 days; (e)test notification not provided to the EHD at least 48 hours prior to conducting an installation, <br /> repair, replacement,calibration,or certification; (f)performed,and failed to affix a tag/sticker on each <br /> monitoring equipment cora onent that was certified repaired, or replaced <br /> 25 HSC 25291 Annual line leak detector test not performed (MI) <br /> 26 HSC 25284.2 Annuals ill containment testing not performed <br /> 27 CCR.2636(f)(4) Annual line tightness test not performed if positive shutdown or fail safe not present M1 <br /> 28 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to permit (1112) <br /> conditions <br /> 29 CCR 2643(e) Biennial tightness test of gravity pipingnot performed re-Janus 1, 1984 Mr <br /> 30 CCR 2643(d) Triennial line test for conventional suction piping not performed re-Janus 1 1964 Mr <br /> 31 HS 25292.5 ELD testing not performed on a system located within 1000'of public well,or failures not repaired and <br /> retested <br /> 32 CCIR 2661 1 Permit toreair UST system not obtained <br /> 33 HS 125286(a) Opera ional ermit not amended when UST storage and/or monitoring system changed <br /> 34 HS 125298(b) Permit to temporary close UST system not obtained <br /> 35 HS 25298(c) Permit to close UST system not obtained <br /> 36 HS 25299 2 Tempe inwith or disabling leak detection devices or alarms <br /> 37 HS 25298 a Illegally abandoned UST system <br /> 38 HS 25281.5 b 2 Unburied fuel piping at marinas not visually inspected at least daily or log not ke t <br /> 39 CC 2631.1 a UST system is not compatible with the substance stored <br /> Emergency enerator systems <br /> 40 CCR 2636 6 me enc enerator monitoringsystem not checked dailyor to not kept if no leak detector Mt <br /> 41 H-S 25281.5 b 3)T_-nburied fuel i in not visually inspected at least monthly or log not kept Mt <br /> AB 1702(2003-2004) HSC 25290.2(installed between 07/01/03 and 08/30/04) <br /> VPH Systems HSC 25290.1 installed on or atter 07/01/04 <br /> Compatibility and permeability requirements: (a)UST system is not compatible with the substance <br /> 42 CCR 2631.1 stored; (b)results of the compatibility and permeability testing requirements listed in subsections CCR <br /> 2631 b and d for a UST system installed after July 1,2004,were not submitted <br /> 43 HSC 25290.1(c)(1) Primary containment not liquid or vapor tight <br /> HSG 25290.2 c 1 <br /> 44 HSC 252 9 0.290. c2 1(c)(2) Secondary containment not liquid or vapor tight <br /> HSC 252 <br /> 45 HSC 25290.1(c)(3) Secondary containment not constructed to prevent water intrusion <br /> HSC 25290.2(c)(3) <br /> 46 HSC 25290.1(d) Monitoring system not maintained to detect water intrusion into the secondary containment, or fall <br /> HS 25290.2(d) the entry of liquid or vapor from the primary containment into the secondary containment <br /> 47 HS 25290.1(e) Interstitial liquid measurement method,constant vacuum, or constant pressure in the interstitial frail <br /> Space of the UST system not maintained <br /> HS 25290.10) UST system not tested by one of the following methods prior to use: (1)Enhanced leak detection; (2) <br /> 48 HSC 25290.2(i) inert gas pressure test approved by SWRCB; (3)test method deemed equivalent to(1)or(2)by the <br /> SWRCB <br /> Other violations <br /> 999 Oth r: See attached"Continuation—Official Inspection Re orf'for violations not listed above. <br /> EHD Inspecro. Phone: UIC <br /> (209) 468-8257 Septic system: <br /> ❑Serves 20 people/day <br /> Recei y Title: ❑Receives other than sanitary waste <br /> Other disposal methods: <br /> `1 / 11 Dry wells/French Drains <br /> EHD 23-02-002'. EV 08/ 0 Page UST INSPECTION REPORT <br />