My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016 - PRESENT
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
26 (STATE ROUTE 26)
>
18754
>
2300 - Underground Storage Tank Program
>
PR0507164
>
COMPLIANCE INFO_2016 - PRESENT
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/20/2024 8:48:35 AM
Creation date
11/8/2018 9:54:07 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - PRESENT
RECORD_ID
PR0507164
PE
2361
FACILITY_ID
FA0007722
FACILITY_NAME
ORLANDOS
STREET_NUMBER
18754
Direction
E
STREET_NAME
STATE ROUTE 26
City
LINDEN
Zip
95236
APN
10517048
CURRENT_STATUS
01
SITE_LOCATION
18754 E HWY 26
P_LOCATION
99
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\T\HWY 26\18754\PR0507164\COMPLIANCE INFO 2016 - PRESENT .PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
1/17/2017 11:13:57 PM
QuestysRecordID
3313957
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
77
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB, January 2002 Page of <br />9. FILL. RISER CONTAINMENT SUMP TESTING F� 9017 <br />Facility is Not Equipped With Fill Riser Containment Sums C <br />Fill Riser Containment Sumps are Present, but were Not Tested ❑ <br />Test Method Developed By: ❑ Sump Manufacturer ❑ Industry Standard X Professional Engineer <br />Other (Spec) <br />Test Method Used: ❑ Pressure ❑ Vacuum X Hydrostatic <br />'I Other (Specify) <br />Test Equipment Used: Caldwell Level Change Indicator <br />Fill Sump #1-91 Fill Sum #2-87 <br />Sum Diameter: 42" 42" <br />Equipment Resolution: .002 <br />Fill Sump # Fill Sump # <br />Sum De the <br />47" <br />50 %d' <br />Height from Tank Top to Top of <br />Hi hest Pi in Penetration: <br />14" <br />13 %" <br />Height from Tank Top to Lowest <br />Electrical Penetration: <br />21" <br />20 %:" <br />Condition of sump prior to <br />testing: <br />Dry <br />Dry <br />Portion of Sump Tested <br />Water Level 23" <br />Water Level 22 VT <br />Sump Material: <br />Fiberglass <br />Fiberglass <br />Wait time between applying <br />water and starting test: <br />5 Minutes <br />5 Minutes <br />Test Start Time: <br />8:47 <br />8:52 <br />Initial Reading (R,): <br />.001 <br />.001 <br />Test End Time: <br />9:17 <br />9:22 <br />Final Reading (RF): <br />.001 <br />.001 <br />Test Duration: <br />30 Minutes <br />30 Minutes <br />Change in Reading RF -R,: <br />0 <br />0 <br />Pass/Fail Threshold or Criteria: <br />.005/30Minutes <br />.005/30Minutes <br />Test Result: <br />Pass <br />Pass <br />Is there a sensor in the sump? <br />Yes <br />Yes <br />Does the sensor alarm when <br />either product or water is <br />detected? <br />Yes <br />Yes <br />Was sensor removed for testing? <br />Yes <br />Yes <br />Was sensor properly replaced and <br />verified functional after testing? <br />Yes <br />Yes <br />Comments — (include information on repairs made prior to testing and recommended follow-up for failed tests) <br />Fill Riser Sump #1 is for Tank #2 Premium Unleaded. <br />Fill Riser Sump #2 is for Tank #3 Regular Unleaded. <br />Tank #1 Diesel, not equipped with Fill Riser Sump! <br />
The URL can be used to link to this page
Your browser does not support the video tag.