Laserfiche WebLink
• i�EGE <br />AUG OAV" January 2006 <br />Spill Bucket Testing Report Form �p��! ��I p <br />This form is intended for use by contractors performing annual testing of UST spill contai>Mtte'h!t h't 9NAY.�', c�L a jorMand <br />printouts from tests (f applicable), should be provided to the facility owner/operator for submittal tD�lr��` ry agency. <br />1. FACILITY INFORMATION <br />Facility Name: ORLANDOS MARKET Date of Testing: 7-11-2017 <br />Facility Address: 18754 E HWY 26 LINDEN CA 95236 <br />Facility Contact: BRANDON Phone: 209-887-1100 <br />Date Local Agency Was Notified of Testing :6-26-17 <br />Name of Local Agency Inspector (ifpresent during testing): STACY SIC <br />ren <br />Company Name: AFFORDA TEST 416 2"d Street Galt, CA 95632 (209) 744-0112 Fax: (209) 744-0116 <br />Technician Conducting Test: ❑ Ed Stearns ❑ Zane A. Nimmo ® David A. Winkler ❑ Felix G. Ramirez <br />8184188 5263322 -UT 5263373 -UT 5273934 -UT <br />Credentials': ® ICC Service Tech. N SWRCB Tank Tester <br />3. SPILL BUCKET TESTING INFORMATION <br />Test Method Used: ® Hydrostatic ❑ Vacuum ❑ Other <br />Test Equipment Used: TAPE / H2O Equipment Resolution: 1/16 <br />Identify Spill Bucket (By Tank <br />Number, Stored Product, etc. <br />1 87 <br />2 91 <br />3 DIESEL <br />4 <br />Bucket Installation Type: <br />ElDirect Bury <br />®Contained in Sump <br />EIDirect Bury <br />® Contained in Sump <br />® Direct Bury <br />El Contained in <br />Sum <br />❑ Direct Bury <br />❑ Contained in <br />Sum <br />Bucket Diameter: <br />11 <br />11 <br />11 <br />Bucket Depth: <br />12 <br />12 <br />14 <br />Wait time between applying <br />vacuum/water and start of test: <br />Test Start Time (Ti): <br />900 <br />900 <br />900 <br />Initial Reading (Ri): <br />11 <br />12 <br />14 <br />'fest End Time (TF): <br />1000 <br />1000 <br />1000 <br />Final Reading (Rp): <br />11 <br />12 <br />14 <br />Test Duration (TF — Tj): <br />1 HOUR <br />1 HOUR <br />1 HOUR <br />Change in Reading (RF -Ri): <br />0 <br />0 <br />0 <br />Pass/Fail Threshold or <br />Criteria: <br />Test Result: <br />® Pass ❑ Fail <br />® Pass ❑ Fail <br />® Pass ❑ Fail <br />❑ Pass ❑ Fail <br />Comments — (include information on repairs made prior to testing, and recommended follow-up for failed tests) <br />CERTIFICATION OF TECHNICIAN RESPONSIBLE FOR CONDUCTING THIS TESTING <br />I hereby certify that all the information contained in this report is true, accurate, and in full compliance with legal requirements. <br />Technician's Signature:. W 7-11-17 <br />' State laws and regulations do not currently require testing to be performed by a qualified contractor. However, local requirements <br />may be more stringent. <br />