My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2007 - 2010
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
THORNTON
>
8606
>
2300 - Underground Storage Tank Program
>
PR0232261
>
COMPLIANCE INFO 2007 - 2010
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/29/2023 1:19:49 PM
Creation date
11/8/2018 9:54:41 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2007 - 2010
RECORD_ID
PR0232261
PE
2361
FACILITY_ID
FA0002590
FACILITY_NAME
THORNTON 76
STREET_NUMBER
8606
STREET_NAME
THORNTON
STREET_TYPE
RD
City
STOCKTON
Zip
95209
APN
07242019
CURRENT_STATUS
01
SITE_LOCATION
8606 THORNTON RD
P_LOCATION
01
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\T\THORNTON\8606\PR0232261\COMPLIANCE INFO 2007 - 2010.PDF
QuestysFileName
COMPLIANCE INFO 2007 - 2010
QuestysRecordDate
2/27/2018 5:13:36 PM
QuestysRecordID
3808429
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
345
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SWRCB,January 2002 Page 2 <br /> 104. TANK ANNULAR TESTING <br /> Test Method Developed By: F-1 Tank Manufacturer ❑x Industry Standard Professional Engineer <br /> 0 Other (Specify) <br /> Test Method Used: F-1 Pressure Vacuum El Hydrostatic <br /> Other (Specify) <br /> Test Equipment Used: Equipment Resolution: <br /> Tank# 2 PLU Tank# 1 PRE Tank# 3 UNL Tank# <br /> Is Tank Exempt From Testing?1 Yes E No Yes El No Yes X No Yes No <br /> Tank Capacity: 10, 000 10, 000 10,000 <br /> Tank Material: DW FIBERG DW FIBERG DW FIBERG <br /> Tank Manufacturer: unknown unknown unknown <br /> Product Stored: PLUS PREMIUM UNLEADED <br /> Wait time between applying <br /> pressure/vacuum/water and 5min 5min 5min <br /> starting test: <br /> Test Start Time: 9:04 9:39 9:42 <br /> Initial Reading(RI ): 10hg 10hg 10hg <br /> Test End Time: 10 :04 10:39 10 :42 <br /> Final Reading(RF ): 10hg 10hg 10hg <br /> Test Duration: 1hr 1hr 1hr <br /> Change in Reading(RF-14 ): 0 0 0 <br /> Pass/Fail Threshold or Criteria: 2 hg 2 hg 2 hg <br /> Test Result: �Pass El Fail Pass El Fail E Pass El Fail 1:1 Pass El Fail <br /> Was sensor removed for testing? YesMN NA❑YesEN NA❑Yes x N NA❑YesE:]No❑NA <br /> Was sensor properly replaced and Pet"-iNcONA� ❑Ye F---1 ❑Ye�Nc�NA E]Yes�NCNA <br /> verified functional after testing? <br /> Comments - (include information on repairs made vrior to testing, and recommended follow-up for failed tests) <br /> t Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing. {California Code of Regulations,Title 23,Section 2637(a)(6)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.