COMPLIANCE INFO 2012-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3775
>
2300 - Underground Storage Tank Program
>
PR0231418
>
COMPLIANCE INFO 2012-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2024 4:19:01 PM
Creation date
11/8/2018 9:55:40 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2015
RECORD_ID
PR0231418
PE
2361
FACILITY_ID
FA0003715
FACILITY_NAME
Tracy Blvd Chevron
STREET_NUMBER
3775
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
3775 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\T\TRACY\3775\PR0231418\COMPLIANCE INFO\COMPLIANCE INFO 2012-2015.PDF
QuestysFileName
COMPLIANCE INFO 2012-2015
QuestysRecordDate
10/10/2017 8:57:48 PM
QuestysRecordID
3096410
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
254
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D.Results of Testing/Servicing <br /> Software version Installed: 123.01 <br /> Complete the following checklist: <br /> IT yes Wthat <br /> s the audible alarm operational? <br /> r yes the visual alarm operational? <br /> r yes ere all sensors visually inspected,functionally tested,and confirmed operational? <br /> r yes ere all Is, <br /> installed at lowest point of secondary containment and positioned so that other equipment will not interfere wilt <br /> eir ro r o eration? <br /> IT Yes alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modem)operational? <br /> r yes or pressurized piping systems,does the turbine automatically shut down if the piping secondary containment monitoring <br /> stem detects a leak,fails to operate,or is electrically disconnected?If yes:which sensors initiate positive shut-down?(Check <br /> ll that apply)r Sump/Trench Sensors; P Dispenser Containment Sensors. <br /> id you confirm positive shut-down due to leaks and sensor failure/disconnection?C• Yes; r No <br /> IT yes r" Noa For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.no mechanical overfill <br /> r" N/A prevention valve is installed),is the overfill warning alarm visible and audible at the tank fill point(s)and operating properly?If <br /> so at what Rercent of tank capacity does the alarm trigger?90% <br /> r Yes* r No Was any monitoring equipment replaced?If yes,identify specific sensors,probes,or other equipment replaced and list the <br /> manufacturer name and model for all re lacemen[parts in Section E below, <br /> r yes* C• No Was liquid found inside any secondary containment systems designed as dry systems?(Check all at apply) <br /> Product r Water.If yes,describe causes in Section E below. <br /> IT yes r No- Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> r Yes r No' Is all monitoring equipment operational per manufacturers specifications? <br /> In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E.Comments: <br /> ATG,208 SENSORS ALL PASS. <br /> Monitoring System Certification Page 2 of 3 12/07 <br />