My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2012-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3775
>
2300 - Underground Storage Tank Program
>
PR0231418
>
COMPLIANCE INFO 2012-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2024 4:19:01 PM
Creation date
11/8/2018 9:55:40 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2015
RECORD_ID
PR0231418
PE
2361
FACILITY_ID
FA0003715
FACILITY_NAME
Tracy Blvd Chevron
STREET_NUMBER
3775
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
3775 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\T\TRACY\3775\PR0231418\COMPLIANCE INFO\COMPLIANCE INFO 2012-2015.PDF
QuestysFileName
COMPLIANCE INFO 2012-2015
QuestysRecordDate
10/10/2017 8:57:48 PM
QuestysRecordID
3096410
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
254
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton,California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.siaov.orci/ehd/unibii.htmi <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT CONTINUED <br /> Facility Facility Inspection <br /> Name: Chevron USA Inc#98264 Address: 3775 North Tracy Blvd, Tracy Date: Feb 3, 2012 <br /> VIOLATIONIS <br /> ff ci C2 NI Code SectionHSC=CA Health and Safet Code;CFR=Code of Federal Regulations <br /> C1=Class 1 violation;C2=Class 2 Nolation;M=Minor violation <br /> Non-Pressurtaed Piping(continued) <br /> 702 CCR 2643(e) Biennial tightness test of gravity piping not performed(pre-January 1,1984) (M1) <br /> 703 CCR 2643(d) biennial line test for conventional suction piping not performed(pre-January 1,1984) (M1) <br /> Other Violations <br /> 999 Other See attached"Continuation—Official Inspection Report"for violation(s)not listed above. <br /> SUMMARY OF VIOLATIONS <br /> CLASS I,CLASS II or MINOR-Notice to Com <br /> UST Inspection: Routine and Annual Monitoring System Certification <br /> 305. All the fill sump sensors Beaudreau failed to activate an audible and visual alarm when tested to <br /> ensure continuous monitoring of the tank system. All monitoring equipment shall be maintained to <br /> activate an audible and visual alarm or stop the flow of product at the dispenser when it detects a leak. <br /> Correct immediately by having a properly licensed, trained, and certified contractor replace the failed <br /> component with a functional component (LG 113-x listed, if applicable). <br /> 310. Liquid was observed: approximately less than: 1/2 gallon in Regular, 1 gallon in Plus and 1/2 gallon <br /> in Supreme of all the fill sumps. If water could enter into the secondary containment by precipitation or <br /> infiltration, it must be removed and disposed of properly. Immediately remove this liquid, make a <br /> hazardous waste determination per Title 22 hazardous waste regulations, and manage it accordingly. <br /> Ensure that the fill sumps are maintained free of liquid. <br /> - Technician remove liquid into hazardous waste drums on site <br /> Submit to SJC EHD within 30 days (03/05/12): <br /> 1. one copy of the completed "Return to Compliance Certification" <br /> 2. a written corrective action statement <br /> Notes: <br /> - Provided free training course schedule. Recommended course: UST for owners/operators, Hazardous <br /> & Universal Waste management <br /> ALL EHD STAFF TIME ASSOCIATED WITH FAILING TO COMPLY BY THE ABOVE NOTED DATES WILL BE BILLED AT THE CURRENT HOURLY RATE. <br /> THIS FACILITY IS SUBJECT TO REINSPECTION AT ANY TIME AT EHD'S CURRENT HOURLY RATE. <br /> In Rewivetl By. Title: <br /> p <br /> EHD 23-02 Rev 09/ /11 I Page 3 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.