My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2012-2015
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3775
>
2300 - Underground Storage Tank Program
>
PR0231418
>
COMPLIANCE INFO 2012-2015
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/21/2024 4:19:01 PM
Creation date
11/8/2018 9:55:40 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2012-2015
RECORD_ID
PR0231418
PE
2361
FACILITY_ID
FA0003715
FACILITY_NAME
Tracy Blvd Chevron
STREET_NUMBER
3775
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
3775 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\T\TRACY\3775\PR0231418\COMPLIANCE INFO\COMPLIANCE INFO 2012-2015.PDF
QuestysFileName
COMPLIANCE INFO 2012-2015
QuestysRecordDate
10/10/2017 8:57:48 PM
QuestysRecordID
3096410
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
254
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
11111109 1..09 <br /> San Joaquin County <br /> Environmental Health Department <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone: (209) 468-3420 Fax: (209) 468-3433 Web:www.sigov.org/ehd <br /> Underground Storage Tank Program Inspection Report <br /> Facility Name: Facility Address: Date: <br /> CHEVRON USA INC#98264' 3775 N TRACY BLVD, TRACY February 17, 2015 <br /> UST System Observations <br /> 322 72636(�(2) Line leak detector not installed o V o R ❑COS <br /> 323 Leak detector failed to detect a 3.0 gph leak at 10 psi o V o R ❑COS <br /> 324 No spill bucket installed or failed to provide a means to keep it empty ❑V ❑R ❑COS <br /> 325 Spill container failed to contain a minimum capacity of five gallons ❑V a R o COS <br /> 326 Overtill prevention system not present,was overridden,or failed to meet overfll requirements ❑V ❑R ❑COs <br /> 327 HSC 25283.5 Unburied below grade UST failed to meet exemption status o V o R o COS <br /> 328 CCR 2717.1(g) Tampered with red tag o V ❑R ❑COS <br /> 329 CCR 2717.1(f) Deposited petroleum into a red tagged UST a V ❑R o COS <br /> 330 HSC 25299(f)(2) Tampered with or disabled leak detection devices or alarms ❑V o R ❑COS <br /> 331 CCR 2631.1 UST system not compatible with the substance stored in V n R n COS <br /> 332 HSC 25298(b) Failed to comply with temporary closure requirements ❑V o R ❑COS <br /> 333 HSC 25298(c) Failed to comply with permanent closure requirements o V ❑R ❑COS <br /> Non-Pressurized Piping ' <br /> 401 CCR 2636(a)(3) Suction piping not properly sloped or incorrectly located check valve o V ❑R a COS <br /> 402 CCR 2643(d) Daily monitoring of suction pipe(pre-Jan 1984)not performed o V ❑R n COS <br /> 403 CCR 2643(d) Triennial 0.1 gph line test for conventional suction piping not performed(pre-January 1984) ❑V ❑R ❑COS <br /> 404 CCR 2643(e) Biennial 0.1 gph test for gravity piping not performed(pre-January 1984) ❑V o R ❑COS <br /> Other Violations <br /> 2010 See below Unlisted Administration/Documentation violation ❑V ❑R ❑COS <br /> 2030 See below Unlisted Operations/Maintenance violation ❑V ❑R c COS <br /> 2060 See below Unlisted Design/Construction violation ❑V ❑R o COS <br /> SUMMARY OF VIOLATIONS <br /> (CLASS I,CLASS II,or MINOR-Notice to Comply) <br /> Item# Remarks <br /> 319 HSC 25291(e)Water in secondary containment not removed, analyzed, and properly disposed of(pre-Jul 2003). <br /> Liquid was observed in the 87 and the 89 STPs. If water could enter into the secondary containment by <br /> precipitation or infiltration, it must be removed and disposed of properly. Immediately remove this liquid, make a <br /> hazardous waste determination per Title 22 hazardous waste regulations, and manage it accordingly. Ensure that <br /> the 87 and 89 STPs are maintained free of liquid. Within 30 days submit a statement addressing how this violation <br /> was corrected. <br /> Overall Inspection Comments: <br /> A checklist of violations was left onsite with a full written report mailed certified 2/17/2015. Violation 302 was <br /> removed. Violation 310 marked on the checklist is seen as violation 319 on the full written report. <br /> Complete and submit a copy of the Return to Compliance Certification form to the EHD with a statement <br /> documenting the corrective actions that have been or will be taken for each violation, and any supporting <br /> paperwork, within 30 days of receiving certified mailing. <br /> Received by(initial): Inspector: Phone: ate: <br /> MICHELLE HENRY, Senior REHS (209)468-3454 02/17/2015 <br /> Page 3 of 4 <br />
The URL can be used to link to this page
Your browser does not support the video tag.