My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2017
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
T
>
TRACY
>
3775
>
2300 - Underground Storage Tank Program
>
PR0231418
>
COMPLIANCE INFO_2017
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/28/2023 4:26:02 PM
Creation date
11/8/2018 9:55:45 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2017
RECORD_ID
PR0231418
PE
2361
FACILITY_ID
FA0003715
FACILITY_NAME
Tracy Blvd Chevron
STREET_NUMBER
3775
Direction
N
STREET_NAME
TRACY
STREET_TYPE
BLVD
City
TRACY
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
3775 N TRACY BLVD
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\T\TRACY\3775\PR0231418\COMPLIANCE INFO\COMPLIANCE INFO 2017 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO 2017 - PRESENT
QuestysRecordDate
6/12/2017 11:15:57 PM
QuestysRecordID
3428349
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
170
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Results of Testing/Servicing <br /> Software Version Installed. 123.01 'P, <br /> FMYe& E] <br /> llowin checklist: <br /> No` Is the autlible alarm operational?No' Is thevisual.alarm operational? <br /> No- Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> No' Were all sensors installed at lowest point of secontlary containment and positioned so that other equipmeMerfeehtuh:ewith their properoperation?No' If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.,modem)operatioN/ANo' For pressurized piping systems,does the turbine automatically shut down if the piping secontlary containmem detects a leak,N/A fails to operate, or is electrically disconnected? If yes: which sensors initiate positive shut-0own? (Che ® SumplTrench <br /> Sensors; ®Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? ®Yes; ❑No. <br /> FYes ❑ No' For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.,no mechanical overfill prevention valve is <br /> N/A installed),is the overall warning alarm visible and autlible at the tank fill point(s)and operating properly? If so,al what percent of tank capacity <br /> does the alarm trigger?® No Was any monitoring equipment replaced? If yes,identify specific sensors,probes,or other equipment replaced and list the manufacturer name <br /> and model for all replacement parts in Section E,below. <br /> ® No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> ❑product; ❑Water. If yes,describe causes in Section E,below❑ No' Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> ❑ No' I Is all monitoring equipment operational per manufacturers specifications? <br /> In Section E below,describe how and when these deficienclea were or will be connected. <br /> HAD TO REPLACE GASKET IN 87 BUCKET THEN PASSED TEST . GARRETT WITH SJC EH ON SITE <br /> E. comments: ALL PASSED <br /> _ M <br /> Monitoring System Certification Page 2 of 4 2/21/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.