Laserfiche WebLink
%r .r <br /> Monitoring System Certification �is�OC <br /> D. Results of Testing/Servicing <br /> Software Version Installed: <br /> Complete the following checklist: <br /> 0 Yes ❑ No* Is the audible alarm operational" <br /> * Yes ❑ No* Is the visual alarm operational? <br /> © Yes ❑ No* Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> 0 Yes ❑ No* Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> not interfere with their proper operation? <br /> ❑ Yes ❑ No* If alarms are relayed to a remote monitoring station, is all communications equipment (e.g. modem) <br /> 0 NIA operational? <br /> ❑ Yes ❑ No* For pressurized piping systems, does the turbine automatically shut down if the piping secondary containment <br /> 0 N/A monitoring system detects a leak,fails to operate,or is electrically disconnected? If yes: which sensors initiate <br /> positive shut-down? (Check all that apply) ❑ Sump/Trench Sensors; ❑ Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failure/disconnection? ❑ Yes; ❑No. <br /> ❑ Yes ❑ No* For tank systems that utilize the monitoring system as the primary tank overfill warning device (i.e. no <br /> 0 N/A mechanical overfill prevention valve is installed), is the overfill warning alarm visible and audible at the tank <br /> fillpoint(s)and operating ro erl ? If so,at what percent of tank capacity does the alarm trigger? <br /> ❑ Yes* 0 No Was any monitoring equipment replaced? If yes,identify specific sensors,probes,or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E,below. <br /> ❑ Yes* 21 No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> ❑ Product; ❑ Water. If yes,describe causes in Section E,below. <br /> 0 Yes I ❑ No* Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports, if applicable <br /> 0 Yes I ❑ No* Is all monitoring equipment oerational per manufacturer's specifications? <br /> * In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: Mechanical overfill prevention valve (Flapper) is installed in tank fill riser. <br /> UN-036-214 Page 2 of 4 Rev.06/04/01 <br /> www.unidocs.orr <br />