Laserfiche WebLink
�*Wv 441111111111, <br /> Home»Water Issues 5 Programs o Ust a> Leak Prevention >>Lgl13 -»Vendors <br /> [an error occurred while processing this directive] <br /> UST Programs - LG 113 <br /> Issue Date:November 22,1995 <br /> Revision Date:May 15,2008 <br /> Veeder•Root <br /> TLS 350,350PC,350R,350RPC,350PIus,450,Red Jacket ProMax Leak Detector,Series 8484 <br /> AUTOMATIC ELECTRONIC LINE LEAK DETECTOR <br /> Certification Leak rate of 3.0 gph at 10 psi`with PD=100%and PFA=0%. <br /> Leak rate of 0.2 gph at operating pressure with PD=100%and PFA=0%. <br /> Leak rate of 0.1 gph at 1.5 times operating pressure'with PD=100%and PFA=0%. <br /> 'Since leak rate varies as a function of pressure,this leak rate and pressure were certified using an equivalent <br /> leak rate and pressure,in accordance with an acceptable protocol. <br /> Leak Threshold 1.88 gph for leak rate of 3.0 gph. <br /> 0.17 gph for leak rate of 0.2 gph. <br /> 0.05 gph for leak rate of 0.1 gph. <br /> A pipeline system should not be declared tight if the test result indicates a loss that equals or exceeds this <br /> threshold. <br /> Applicability Gasoline,diesel,aviation fuel. <br /> Other liquids may be tested after consultation with the manufacturer. <br /> Specification System tests pressurized fiberglass and steel pipelines. <br /> Tests are conducted at operating pressure. <br /> System will not function with a mechanical line leak detector installed in the pipeline. <br /> Pipeline Capacity Maximum of 98.4 gallons. <br /> Waiting Time None between delivery and testing. <br /> Minimum of 16 minutes between dispensing and testing for leak rate of 3.0 gph. <br /> Minimum of 45 minutes to 1 hour between dispensing and testing for leak rate of 0.2 gph. <br /> Minimum of 2 hours,30 minutes between dispensing and testing for leak rate of 0.1 gph. <br /> Test Period Response time is 28.8 seconds for leak rate of 3.0 gph. <br /> Response time is 32 to 48 minutes for leak rate of 0.2 gph. <br /> Response time is 18 minutes for leak rate of 0.1 gph. <br /> Test data are acquired and recorded by a microprocessor. <br /> Calculations are automatically performed by the microprocessor. <br /> System Features Permanent installation on pipeline. <br /> Automatic testing of pipeline. <br /> Preset threshold. <br /> Single test to determine if pipeline is leaking. <br /> Pump shutdown(optional),message display and alarm activation if leak is declared. <br /> Calibration Equipment must be checked annually for capability of detecting a line leak of 3.0 gph and,if <br /> necessary,calibrated in accordance with manufacturer's instructions. <br /> Veeder-Root Evaluator: Midwest Research Institute <br /> 125 Powder Forest Dr. Tel: (816)753-7600 <br /> Simsbury,CT 06070-2003 Date of Evaluation: 08/07/91, 12/18/96 <br /> Tel: (860)651-2700 <br /> E-mail:dhalla@veedercorn Evaluator:Ken Wilcox Associates <br /> URL:www.veeder.com/dynamic/index.cfm Tel:(816)443-2494 <br /> Dates of Evaluation:2/27/2008 <br /> http://www.swrcb.ca.gov/water_issues/programs/ust/I eak_preventi on/I gI 13/vendors/veeder_root_c.shtml <br />