Laserfiche WebLink
2.2.3.2.When using multiple lifting lugs,the angle of the lifting ways take extra care so that the bottom sump or fitting is not <br /> sling should never exceed 30 degrees—see FIGURE 2-1. damaged by contact with any other object,such as the truck <br /> bed or the ground. <br /> j 2.3. STORING TANKS <br /> 2.3.1.Whenever a tank is temporarily placed above the <br /> ground at the site,place it on a smooth,solid, level area that is <br /> clear of large rocks,trash and debris,and then chock it in <br /> place to prevent rolling.See FIGURE 2-3. <br /> A WARNING <br /> Always chock the tank.The tank is heavy and has a large <br /> surface area.The tank will roll on sloped surfaces and could <br /> be blown about by the wind.Movement of the tank could re- <br /> sult in death or serious injury. <br /> 30-degree 2.3.2.Tie the tank down if high winds are expected. Do not <br /> ma>omum use wire rope or chains.See FIGURE 2-3. <br /> 2.3.2.1. Never place tie-down straps over collars or reservoirs. <br /> FIGURE 2-1 <br /> 2.2.3.3.When the tank is not rotated(the tank is upright), use Tie <br /> all liking lugs to unload and install the tank.See FIGURE 2-2. Downs <br /> 2.2.3.4.Some tanks are rotated on the truck for shipping pur- Sandbags Tank Tres <br /> poses.These tanks have extra lifting lug(s)to aid in the load- <br /> ing/unloading process.See FIGURE 2-2. <br /> 2.2.3.4.1.To unload these tanks,use the lifting lugs that are <br /> situated on top of the tank in its rotated position. <br /> 2.2.3.4.2.To install the tank,carefully rotate the tank to its up- <br /> right position and then use all lifting lugs situated on top of the FIGURE 2-3 <br /> tank in its upright position.See FIGURE 2-2. 2.3.3.Whenever a tank is temporarily placed above the <br /> ground at the site,always take extra care so water does not <br /> Top of tank in rotated position enter the collar.Xerxes recommends that the tank be rotated <br /> and/or the collar covered. <br /> Lifting lugs to be Lifting lugs to be <br /> used when tank is in t used when tank is in CAUTION <br /> upright position rotated position If water enters the collar,it could freeze and may result in <br /> damage to the tank and/or collar. <br /> 2.3.4.Ensure that the tank is UV-protected if it will be stored <br /> above the ground for an extended period of time,typically 12 <br /> Top of tank in upright position months depending on the geographic location of installation. <br /> t 3. PREINSTALLATION INSPECTION <br /> Lifting lugs to be AND TESTING <br /> used when tank is in <br /> upright position 3.1. GENERAL <br /> A WARNING <br /> Do not conduct preinstallation testing while the tank is on a <br /> trailer.Failure to follow this warning could result in death or <br /> serious injury. <br /> FIGURE 2-2 1 CAUTION <br /> 2.2.4. Do not wrap chain or cable around the tank at any time, Do not put product in the tank until all necessary preinstalla- <br /> including when securing the tank on the ground. tion inspection and testing is completed.Failure to follow <br /> this caution may result in property damage. <br /> 2.2.5. Use guide ropes to guide the tank when needed. <br /> 2.2.6.When handling a tank with a bottom sump or fitting,al- <br /> 3 <br />