Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VALPICO
>
550
>
2300 - Underground Storage Tank Program
>
PR0536555
>
INSTALL_2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
11/25/2019 3:22:40 PM
Creation date
11/8/2018 9:57:13 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2012
RECORD_ID
PR0536555
PE
2351
FACILITY_ID
FA0020989
FACILITY_NAME
Arco. Am pm 83333
STREET_NUMBER
550
Direction
W
STREET_NAME
VALPICO
STREET_TYPE
Rd
City
Tracy
Zip
95376
CURRENT_STATUS
01
SITE_LOCATION
550 W Valpico Rd
P_LOCATION
03
P_DISTRICT
005
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\V\VALPICO\550\PR0536555\INSTALL PLAN 2012.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
373
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Sump Entry/Termination Fitting with Bonded Fiberglass Alignment Rings <br /> thick to the inside and the out- visible between the rings and it. The use of an industrial hot air <br /> side of the sump walls where the the sump wall.The metal ring gun may speed up the curing <br /> alignment rings are located.Coat must hold the assembly in posi- process. Do not overheat. <br /> cut edges of the entry hole.Apply tion while the adhesive cures.If 12.Remove 1/4"plastic threaded out- <br /> a thin coating of adhesive to the the assembly is not tight against let protector.Apply adhesive to <br /> bonding surface of the two rings the sump wall,firmly press the the 1/4"fitting and screw into the <br /> that will bond to the sump walls. entry fitting against the outside 1/4"threaded outlet.Tighten to <br /> S. Line up rings with alignment sump wall while pressing the 40 in.-lbs.or 11/2-2 turns past <br /> marks and press together firmly. metal ring against the alignment hand tight. After installing fitting, <br /> 9. Slide the metal retaining ring over ring on the inside. be sure the interstitial space is free <br /> inside section of sump fitting 10.Do not disturb assembly until the from excess adhesive. Install a <br /> against the alignment rings until adhesive is cured.This includes short hose and blow excess adhe- <br /> they are tight against sump wall. bonding of pipe to the entry fitting sive through the air passage. <br /> (A short section of 4"pipe may be and installing the threaded outlet 13.Connect only flexible tubing or <br /> used to drive the metal retaining fitting.Clean excess adhesive from hoses to the 1/4"side-outlet. <br /> ring over the fitting.)Be sure all bonding surfaces.See adhesive Note:Tubing or hoses must be <br /> there is an adhesive bead kit instructions for cure times. rated to full vacuum. <br /> i <br /> 1I1"hose barb adapter <br /> � TERMINATION EXAMPLE using <br /> / <br /> - SUMP ENTRY/TERMINATION FITTINGS <br /> Primary Pipe- <br /> . jj J _______—__ Red Thread IIA <br /> lA <br /> ¢ad <br /> insertion _ <br /> -- -- Concentric Reducer <br /> Make sure air <br /> passage is dear o 0 0 <br /> ( <br /> 0 0 <br /> The 1/4"threads are a"modified NPT"—the insertion of a Thread I Pipe- <br /> fted Thread IIA <br /> standard spec male thread is minimized. Sump Entry/Terminstion Fitting <br /> Smith Fibercast 7014 or 8014 adhesive is recommended. Spigot x NPT Adapter or Spigot x Spigot Nipple <br /> The 1/4"female threads are plastic and cannot be tightened Use concentric reducer to connect the sump entryttermination <br /> the same a metallic thread.Tighten to 40 in-lbs.or 1%a- <br /> 2 turns pastst hard tight. fining to secondary containment pipe;DO NOT USE Gam shell <br /> After installing a 1l4"NPT fitting,the passageway(s)to the termination fittings with this style fitting. <br /> piping interstitial space should be Geared with air pressure to <br /> insure that they are free of thread sealant and/or adhesive. <br /> It is the policy of Smith Fiberoest to improve its products continually. In accordance with that policy,the right is reserved to make <br /> charges in specifications,descriptions,and Illustrative material contained in this bulletin as conditions warrant. The Information con- <br /> tained herein is general in nature and is not intended to express any warranty of any type whatsoever,nor shall any be implied. <br /> Fiber GIaSS SyStww 1w <br /> STAR • SMITH • FIBERCAST <br /> 2700 West 65th Street 'JO 9001 <br /> PEI Little Rock, 672209 <br /> 8-40 <br /> ar�ws. Telephone(501)1)566-4010 r <br /> Fax(501)568-4465 <br /> www.smithfibercastcom arlsrN fAsikNT <br /> PRINTED IN U.5 A 5M0705 ®2005 Nafional Oilwell VarO <br />