My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2016 - PRESENT
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
1400
>
2300 - Underground Storage Tank Program
>
PR0231951
>
COMPLIANCE INFO 2016 - PRESENT
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:25 PM
Creation date
11/8/2018 9:57:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - PRESENT
RECORD_ID
PR0231951
PE
2361
FACILITY_ID
FA0003704
FACILITY_NAME
DART CONTAINER CORP
STREET_NUMBER
1400
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04932015
CURRENT_STATUS
01
SITE_LOCATION
1400 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\V\VICTOR\1400\PR0231951\COMPLIANCE INFO 2016 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
6/2/2016 5:37:57 PM
QuestysRecordID
3102413
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
M`7 mER-RYAN INC. <br />SWRCB, January 2002 <br />4. TANK ANNi H.AR TFCTiNr <br />GR Job # 20-643211 <br />Page 2 of 2 <br />Test Method Developed By: <br />Tank Manufacturer <br />Other (specify) <br />Industry Standard <br />Professional Engineer <br />Test Method Used: <br />Pressure <br />Other (s ecify) <br />Vacuum <br />Hydrostatic <br />Test Equipment Used: <br />Vacuum Gauge- <br />Equipment Resolution: .5 in. hg. <br />Diesel Tank N Tank N <br />Tank # <br />Is Tank Exempt Form Testing? (1) <br />Yes <br />No X Yes <br />No <br />Yes <br />No Yes No <br />Tank Capacity: <br />10,000 <br />Tank Manufacturer: <br />UNK <br />Product Stored: <br />Diesel <br />Wait time between applying <br />Pressure/vacuum/water and <br />starting test: <br />lUmin <br />r <br />Test Start Time: <br />11:15 <br />Initial Reading (Ri): <br />-7" <br />Test End Time: <br />12:15 <br />ENVIR <br />Final Reading (RO <br />-7" <br />EPARTINEN <br />Test duration: <br />1 hr <br />Chane in Reading (Rf-Ri): <br />0 <br />Pass/Fail Threshold or Criteria: <br />0 <br />Test Results: <br />x Pass <br />Fait Pass <br />Fail <br />Pass <br />Fail I Pass Fail <br />Was sensor removed for testing? <br />Yes <br />No NA Yes No <br />NA <br />Yes <br />No NA Yes No NA <br />Was sensor properly replaced and <br />verified functional after testin ? <br />Yes <br />No NA Yes No <br />NA <br />Yes <br />No NA Yes No NA <br />Comments - (include information on repairs made prior to testing, and recommend follow-up for failed tests) <br />(1) Secondary containment system where the continuous monitoring automatically monitors both the primary and secondary <br />containment, such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br />testing. (California Code of Regulations, Title 23, Section 2637(a)(6)) <br />W <br />IL <br />
The URL can be used to link to this page
Your browser does not support the video tag.