Laserfiche WebLink
SAN JOAQUIN <br />-CC U rY-- <br />Environmental Health Department <br />FA0003704 PRO231951 SCO01 12126@017 <br />EHD 2&01 Rev. 1013V2017 Page 3 of S underground Storage Tank Program OR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />DART CONTAINER CORP <br />Facility Address: <br />1400 E VICTOR RD, LODI <br />Date: <br />December 26, 2017 <br />UST System Observations <br />319 <br />CCR 2635(b) <br />No spill bucket, failed to contain five gallons, or failed to provide a means to keep it empty <br />o V o R o COS <br />320 <br />CCR 2635(b)(2) <br />Overfill prevention system not present or failed to meet overall requirements <br />o V o R in COS <br />321 <br />CCR 2635(b)(2) <br />Overfill prevention was overridden <br />c V in R o COS <br />322 <br />HSC 25281.6(a) <br />Unburied below grade emergency generator system failed to meet exemption status <br />in V o R o COS <br />323 <br />HSC 25283.5(a) <br />Unburied below grade UST system failed to meat exemption status <br />o V in R in COS <br />324 <br />CCR 2717.1(g) <br />Tampered with red tag <br />o V o R o COS <br />325 <br />CCR 2717.1(1) <br />Deposited petroleum into a red tagged UST <br />o V o R in COS <br />326 <br />HSC 25299(x)(9) <br />Tampered with or disabled leak detection devices or alarms <br />in V o R o COS <br />327 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />n V o R o COS <br />328 <br />HSC 25298 <br />Failed to comply with temporary closure requirements <br />o V in R o COS <br />329 <br />HSC 25298 <br />Failed to comply with all permanent closure requirements <br />in V c R 0 COS <br />330 <br />CCR 2838(1)(8) <br />Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system <br />o V 0 R o COS <br />331 <br />CCR 2630(d) <br />Secondarily contained piping not maintained to allow liquid to drain into sump <br />o V o R in COS <br />332 <br />CCR 2631(b), 2631(d) <br />Primary and/or secondary containment not constructed in accordance with the established standards <br />o V 0 R o COS <br />Single -Waited Non -Pressurized Piping <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />n V in R o COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />o V o R o COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1964) <br />in V o R o COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />o V o R n COS <br />Other Violations <br />2010 <br />See below <br />Unlisted General violation <br />V - R _ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />107 <br />CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br />An accurate UST Monitoring Site Plan was not submitted. Site map is lacking general pipe layout. A site plan must <br />be submitted identifying the locations where monitoring will be performed. Immediately log into the California <br />Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/ and upload a copy of the UST Monitoring Site <br />Plan. <br />This is a minor violation. <br />FA0003704 PRO231951 SCO01 12126@017 <br />EHD 2&01 Rev. 1013V2017 Page 3 of S underground Storage Tank Program OR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />