My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2016 - PRESENT
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
1400
>
2300 - Underground Storage Tank Program
>
PR0231951
>
COMPLIANCE INFO 2016 - PRESENT
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:25 PM
Creation date
11/8/2018 9:57:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - PRESENT
RECORD_ID
PR0231951
PE
2361
FACILITY_ID
FA0003704
FACILITY_NAME
DART CONTAINER CORP
STREET_NUMBER
1400
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04932015
CURRENT_STATUS
01
SITE_LOCATION
1400 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\V\VICTOR\1400\PR0231951\COMPLIANCE INFO 2016 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
6/2/2016 5:37:57 PM
QuestysRecordID
3102413
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN <br />-CC U rY-- <br />Environmental Health Department <br />FA0003704 PRO231951 SCO01 12126@017 <br />EHD 2&01 Rev. 1013V2017 Page 3 of S underground Storage Tank Program OR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />DART CONTAINER CORP <br />Facility Address: <br />1400 E VICTOR RD, LODI <br />Date: <br />December 26, 2017 <br />UST System Observations <br />319 <br />CCR 2635(b) <br />No spill bucket, failed to contain five gallons, or failed to provide a means to keep it empty <br />o V o R o COS <br />320 <br />CCR 2635(b)(2) <br />Overfill prevention system not present or failed to meet overall requirements <br />o V o R in COS <br />321 <br />CCR 2635(b)(2) <br />Overfill prevention was overridden <br />c V in R o COS <br />322 <br />HSC 25281.6(a) <br />Unburied below grade emergency generator system failed to meet exemption status <br />in V o R o COS <br />323 <br />HSC 25283.5(a) <br />Unburied below grade UST system failed to meat exemption status <br />o V in R in COS <br />324 <br />CCR 2717.1(g) <br />Tampered with red tag <br />o V o R o COS <br />325 <br />CCR 2717.1(1) <br />Deposited petroleum into a red tagged UST <br />o V o R in COS <br />326 <br />HSC 25299(x)(9) <br />Tampered with or disabled leak detection devices or alarms <br />in V o R o COS <br />327 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />n V o R o COS <br />328 <br />HSC 25298 <br />Failed to comply with temporary closure requirements <br />o V in R o COS <br />329 <br />HSC 25298 <br />Failed to comply with all permanent closure requirements <br />in V c R 0 COS <br />330 <br />CCR 2838(1)(8) <br />Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system <br />o V 0 R o COS <br />331 <br />CCR 2630(d) <br />Secondarily contained piping not maintained to allow liquid to drain into sump <br />o V o R in COS <br />332 <br />CCR 2631(b), 2631(d) <br />Primary and/or secondary containment not constructed in accordance with the established standards <br />o V 0 R o COS <br />Single -Waited Non -Pressurized Piping <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />n V in R o COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />o V o R o COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1964) <br />in V o R o COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />o V o R n COS <br />Other Violations <br />2010 <br />See below <br />Unlisted General violation <br />V - R _ COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />107 <br />CCR 2632(d)(1)(C) Plot plan/site map not submitted or failed to completely show where monitoring is performed. <br />An accurate UST Monitoring Site Plan was not submitted. Site map is lacking general pipe layout. A site plan must <br />be submitted identifying the locations where monitoring will be performed. Immediately log into the California <br />Environmental Reporting System (CERS) at http://cers.calepa.ca.gov/ and upload a copy of the UST Monitoring Site <br />Plan. <br />This is a minor violation. <br />FA0003704 PRO231951 SCO01 12126@017 <br />EHD 2&01 Rev. 1013V2017 Page 3 of S underground Storage Tank Program OR <br />1868 E. Hazelton Avenue I Stockton, California 95205 1 T 209 468-3420 1 F 209 464-0138 1 www.sjcehd.com <br />
The URL can be used to link to this page
Your browser does not support the video tag.