My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2016 - PRESENT
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
1400
>
2300 - Underground Storage Tank Program
>
PR0231951
>
COMPLIANCE INFO 2016 - PRESENT
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:25 PM
Creation date
11/8/2018 9:57:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016 - PRESENT
RECORD_ID
PR0231951
PE
2361
FACILITY_ID
FA0003704
FACILITY_NAME
DART CONTAINER CORP
STREET_NUMBER
1400
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04932015
CURRENT_STATUS
01
SITE_LOCATION
1400 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\V\VICTOR\1400\PR0231951\COMPLIANCE INFO 2016 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO 2016 - PRESENT
QuestysRecordDate
6/2/2016 5:37:57 PM
QuestysRecordID
3102413
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
53
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
FA0003704 PR0231951 SCO01 12/09/2016 <br />EHD 23-01 Rev. 09/22/16 Page 3 of 4 Underground Storage Tank Program OIR <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Far: (209) 468-3433 Web: www.siaov.ora/ehd <br />Underground Storage Tank Program Inspection Report <br />Facility Name: <br />DART CONTAINER CORP <br />Facility Address: <br />1400 E VICTOR RD, LODI <br />Date: <br />December 09, 2016 <br />UST System Observations <br />323 <br />HSC 25283.5(a) <br />Unburied below grade UST system failed to meet exemption status <br />❑ V ❑ R <br />❑ V ❑ R <br />- COS <br />❑ COS <br />324 <br />CCR 2717.1(g) <br />Tampered with red tag <br />325 <br />CCR 2717.1(f) <br />Deposited petroleum into a red tagged UST <br />❑ V ❑ R <br />❑ COS <br />326 <br />HSC 25299(a)(9) <br />Tampered with or disabled leak detection devices or alarms <br />❑ V ❑ R <br />a COS <br />327 <br />CCR 2631.1 <br />UST system not compatible with the substance stored <br />❑ V ❑ R <br />❑ COS <br />328 <br />HSC 25298 <br />Failed to comply with temporary closure requirements <br />❑ V ❑ R <br />o COS <br />329 <br />HSC 25298 <br />Failed to comply with permanent closure requirements <br />❑ V ❑ R <br />❑ COS <br />330 <br />CCR 2636(0(6) <br />Failure to meet all requirements in lieu of a line leak detector for emergency generator tank system <br />❑ V e R <br />.- COS <br />Single -Walled Non -Pressurized Piping <br />401 <br />CCR 2636(a)(3) <br />Suction piping not properly sloped or incorrectly located check valve <br />_ V � R <br />� COS <br />402 <br />CCR 2643(d) <br />Daily monitoring of suction pipe (pre -Jan 1984) not performed <br />o V ❑ R <br />❑ COS <br />403 <br />CCR 2643(d) <br />Triennial 0.1 gph line test for conventional suction piping not performed (pre -January 1984) <br />❑ V ❑ R <br />❑ COS <br />404 <br />CCR 2643(e) <br />Biennial 0.1 gph test for gravity piping not performed (pre -January 1984) <br />o V ❑ R <br />u COS <br />Other Violations <br />2010 <br />See below <br />Unlisted Administration/Documentation violation <br />❑ V ❑ R <br />❑ COS <br />2030 <br />See below <br />Unlisted Operations/Maintenance violation <br />❑ V ❑ R <br />❑ COS <br />2060 <br />See below <br />Unlisted Design/Construction violation <br />r- V - R <br />-. COS <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS Il, or MINOR - Notice to Comply) <br />Item # <br />Remarks <br />103 <br />HSC 25292.2 Current financial responsibility documents not submitted. <br />Financial responsibility documents have not been submitted to the Environmental Health Department (EHD). <br />Current financial responsibility documents are required to be submitted annually. During the inspection the Safety <br />Leader uploaded the current Certification of Financial Responsibility documents into the California Environmental <br />Reporting System (CERS) at http://cers.calepa.ca.gov/. <br />This was corrected on site. <br />This is a repeat violation, Class II. <br />104 <br />CCR 2711 UST operating permit application for facility and tank information not submitted or current. <br />UST Tank Information forms for TA0195102 are not current in CERS. Beneath Product/Waste Piping Construction, <br />change Piping Construction from "Double -walled" to "Single -walled" and remove "steel' from the Secondary <br />Containment. During the inspection, the Safety Leader made the necessary corrections in California Environmental <br />Reporting System (CERS). <br />This was corrected on site. <br />This is a repeat violation, Class ll. <br />FA0003704 PR0231951 SCO01 12/09/2016 <br />EHD 23-01 Rev. 09/22/16 Page 3 of 4 Underground Storage Tank Program OIR <br />
The URL can be used to link to this page
Your browser does not support the video tag.