7— 6-05: 9:41AM;SacramenX0 EMC ;916 9252816 > <br /> Sacramento Equipment Maintenance Company,Inc Work Order#119676 <br /> Site Address: Valley Pacific Cardloek llate of Testing/Servicing: 06-28-05 <br /> 930 E Victor Road <br /> Lodi,Ca. <br /> D. Results of Testing/Servicing: <br /> Software Version Installed: 2.201 <br /> Yes No N/A Complete the following checklist: <br /> X Is the audible alarm operational? <br /> X Is the visual alarm operational? <br /> X Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> X Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will <br /> - not interfere with their proper operation? <br /> ` X If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.modem)operational? <br /> X For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment Ii <br /> monitoring system detects a leak,fails to operate,or is electrically disconnected? If yes:which sensors initiate <br /> positive shutdown? (Check all that apply) <br /> Sump/Trench: Dispenser Containment Sensors <br /> Did you confirm positive shutdown due to leaks and sensor failure/disconnection? Yes [No <br /> -- <br /> X For tanks systems that utilize the monitoring system as the primary tank overfill warning device(i.e.no <br /> mechanical overfill prevention valve is installed),is the overfill warning alarm visible and audible at the tank fill <br /> point(s)and operating properly? If so,at what percent of tank capacity does the alarm trigger? % <br /> X Was any monitoring equipment replaced? If yes,identify specific sensors,probes or other equipment replaced <br /> and list the manufacturer name and model for all replacement parts in Section E below. <br /> X Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> Product Ej Water If yes,describe causes in Section E below. <br /> X Was monitoring system set-up reviewed to ensure proper settings? <br /> X I Is ala monitoring equipment operational per manufacturer's specifications? ' <br /> (Above shaded boxes need to describe how and when these def;ciencies were or wt14 be c6roted an Section E below), <br /> E. Comments: Only unleaded and premium stp sumo monitor diesel dispensers has bravo box with above around tanks. <br /> no sensors or leak detectors except level overspill buckets unleaded and Premium are 5 gallon OPW swivais <br /> �II <br /> 03/01 worry/OOOOf/svtta2-monilorinycert.wpd Page 2 of 4 <br />