Laserfiche WebLink
SAN JOAQUIN COUNTY <br /> '%�NVIRONMENTAL HEALTH DEPARTMENT,a/ <br /> 304 East Weber Avenue, 3`d Floor, Stockton, CA 95202-2708 <br /> Telephone: (209)468-3420 Fax: (209)468-3433 Web:www.sj ov.org/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> Facility name: Designated Operator: Inspection Date: <br /> \x\k-V' <br /> Facility address: UST# , <br /> QQ)o \ALIvo— Product <br /> Facility Contact: Title: Phone: ; <br /> Monitoring Panel: Pip' g system: O�/eeppfill prevention: <br /> \' �ssurized ❑Suction ❑Gravit 11YMechanical ❑Audible/visual <br /> Infection type: Vig7a[ione: <br /> ,Routine ❑MonitoringCertification D Installation D Other: 4-'YIMa-RDetect ❑M2-RPrev ❑M-3 Both <br /> # Code Section <br /> VIOLATION(S) HSC=Califomia Health&Safety Code;CCR=Califomia Code of Regulations V R V=Violation;RV=Re eat Violation V <br /> 1 HSC 25284 Permit tooperate <br /> 2 CCR 2637 Secondary containment test performed <br /> 3 CCR 2711 6 & c Current Unified Program Consolidated Forms on file with EHD(Facility and tank form <br /> 4 HSC 25292.2 Certification of financial responsibility and CFO letter <br /> 5 CCR 2632 c 2 D Monitoring&response plan is current and filed with the local agency <br /> 6 CCR 2712(i) Monitoring&response plan is onsite <br /> 7 CCR 2712 b Maintenance&monitoringrecords Ml <br /> 8 CCR 2643 d Dail monitoringof suction piping(pre-January, 1, 1984 <br /> 9 HSC 25292.1 UST system isoperated to prevent unauthorized release <br /> 10 CCR 2632(c)(2) UST monitoringsystem is resent (MI) <br /> I I CCR 2630(d UST system monitoringequipment is properly located to detect a leak Ml <br /> 12 HSC 25291 6 UST system monitoringequipment isoperational M2) <br /> 13 CCR 2636 1 Continuous monitoringsystem for underground piping&UDC is resent Ml <br /> 14 CCR 2631 a Primary containment is product tight <br /> 15 1 HSC 25291 (a)(2) Secondary containment for UST is tight <br /> 16 1 CCR 2636(c)(1) All releases in secondary pipingflow to a collection sump <br /> 17 HSC 25291 Line leak detectors are installed M1 <br /> 18 CCR 2635 6 1 Spill container M2 <br /> 19 CCR 2635(b)(2) Overfill prevention system M2 <br /> 20 CCR 2636(a) Conventional suction piping shall have continuous monitoring&20 containment <br /> 21 HSC 25291 (c) Water in 20 containment analyzed&properly disposed of <br /> 22 CCR 2650 Recording/reporting of unauthorized releases Ml <br /> 23 CCR 2715 Designated Operator: (a)Statement from UST owner; (c-e)Monthly inspection;(f)Employee training <br /> 24 CCR 2638 a Annual monitoring certification <br /> 25 CCR 2638(a) Annual line leak detector test (MI) <br /> 26 HSC 25284.2 Annuals ill containment testing <br /> 27 CCR 2636 4 Annual line tightness test MI <br /> 28 CCR 2661 Repair for tank/piping has had tightness test M2 <br /> 29 CCR 2643 e Biennial tightness test of gravity pipingre-Janus I, 1984 <br /> 30 CCR 2643 d Triennial line test for conventional suction piping( re-Jana I, 1984) (MI) <br /> 31 HSC 25292.5 Double walls stem located within 1000'of public well-ELD <br /> 32 CCR 2661 Permit to re air UST system <br /> 33 HSC 25286 a Permit to alter monitoring system <br /> 34 HSC 25298 Permit to temporarily close UST system <br /> 35 HSC 25298 c Permit to close UST system <br /> 36 HSC 25299 a)(9) Disablingleak detection devices <br /> 37 HSC 25298(a) Illegal abandonment of UST system <br /> 38 1 Other: <br /> EHD INSPECTOR: PHONE: UIC <br /> Septic system: <br /> Serves>_20 people/day <br /> RECEIVED BY: TITLE: 7 Receives other than sanitary waste <br /> Other disposal methods: <br /> Dry wells/French Drains <br /> EHD 23-02-002 <br />