My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1985-2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
930
>
2300 - Underground Storage Tank Program
>
PR0502817
>
COMPLIANCE INFO 1985-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
1/3/2024 2:50:15 PM
Creation date
11/8/2018 9:58:08 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985-2006
RECORD_ID
PR0502817
PE
2361
FACILITY_ID
FA0005584
FACILITY_NAME
VALLEY PACIFIC LODI PLANT & CARDLOCK
STREET_NUMBER
930
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04905023
CURRENT_STATUS
01
SITE_LOCATION
930 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\V\VICTOR\930\PR0502817\COMPLIANCE INFO\COMPLIANCE INFO 1985-2006.PDF
QuestysFileName
COMPLIANCE INFO 1985-2006
QuestysRecordDate
5/19/2016 8:14:18 PM
QuestysRecordID
3086574
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
184
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
SAN JOAQUIN COUNTY DATE <br /> `tNVIRONMENTAL HEALTH DEPARTMENT PAGE aaq- <br /> 304 E. Weber Ave., Third Floor, Stockton, CA 95202 <br /> (209)468-3420 <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> Facility Name\*4. ^ 4p<_vc- . Facility Address °4'bo G. vv-xcW- <br /> Facilty Contact 3\N,), Title Phone # <br /> UST# k.., Products_ UST#3PProduct �\ UST#_Product UST#_Product <br /> Overfill Prevention: ❑Audible/Visu��I Mechanical Monitoring Panel: <br /> Piping System: L1 Gravity GY�ressure ❑Suction / Violations: inor 11 Major <br /> Automatic Pum Shut Down Satisfies CCR 2636 (g): H'Yes 0 No Dispenser Pan: es ❑ No <br /> INSPECTION TYPE: CRoutine ❑Monitoring Certification ❑Complaint []Install ❑Removal ORepair/Upgrade <br /> COMPANY NAME: TECHNICIAN NAME: PHONE: <br /> VIOLATION(S) <br /> The above facility is not in compliance with the following section(s) of Health & Safety Code (HSC) and/or <br /> California Code of Regulations (CCR): <br /> 1 HSC 25284 Permit to operate 20 CCR 2712 (b) Maintenance &monitoring <br /> 2 CCR 2637 Secondary cont testing (6 records <br /> month/36 month) 21 CR 2636 (f)(4) Annual line tightness test <br /> 3_LCCR 2711(b) & (c) Current State Forms A& B 22 ✓ CCR 2630 (d) Annual line leak detector test <br /> 4 HSC 25292.2 Certification of financial 23_CCR 2630 (d) Annual monitoring certification <br /> responsibility and letter from 24 CCR 2643 (d) Daily monitoring Of suction <br /> chief financial officer piping that is not continuously <br /> 5 CCR 2630 (d) Continuous monitoring system monitored <br /> for UST system 25 CCR 2636 (a) Conventional suction piping <br /> 6 CCR 2636 (c)(1) All releases in secondary piping shall have continuous <br /> flow to a collection sump monitoring &20 containment <br /> 7 HSC 25291 (e) Water in secondary(20)cont 26CCR 2643 (e) Biennial tightness test of gravit, <br /> 8 HSC 25291 (f) Automatic line leak detector(s) piping that is not continuously <br /> 9 CCR 2636 (f)(1) Continuous monitoring system monitored <br /> for underground piping 27 CCR 2662 Upgrade requirements for UST <br /> 10 CCR 2632 (c)(2) Continuous monitoring system system <br /> for UST 28 CCR 2661 Permit to repair UST system <br /> 11 HSC 25291(a)(2) Secondary containment for 29HSC 25286 (a) Permit to alter monitoring <br /> UST is tight system <br /> 12_CCR 2636 (f)(1) Continuous monitoring system 30 HSC 25298 (a) Illegal abandonment of UST <br /> for dispenser system system <br /> 13_CCR 2635 (b)(1) Spill container 31 HSC 25298 (b) Permit to temporarily close US- <br /> 14 CCR 2635 (b)(2) Overfill prevention system system <br /> 15—CCR 2631 (a) Primary containment is product- 32 HSC 25298 (c) Permit to close UST system <br /> tight 33 HSC 25291 (e) Water in 20 cont analyzed and <br /> 16 HSC 25292.1 UST system is operated to properly disposed of <br /> prevent unauthorized release 34 CCR 2640 (e) Single wall component within <br /> 17 CCR 2650 Recording/reporting 1 000' of Public Well, no ELD <br /> unauthorized release 35CCR 2635(a)(2)(A)Cathodic protection testing <br /> 18 CCR 2632 (d) Monitoring & response plan 36 H&SC 25299(a)(9)Disabling leak detect. devices <br /> 19—ZCCR 2712 (i) Monitoring & response plan is 37 Violation(s) not listed above <br /> on site <br /> EHD INSPECTO PHONE:�tL�6-3�1 <br /> RECEIVED BY: TITLE: <br /> UNITII WSVINSP(w 7!24M) <br />
The URL can be used to link to this page
Your browser does not support the video tag.