My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_JUN 2016 - 2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
V
>
VICTOR
>
930
>
2300 - Underground Storage Tank Program
>
PR0502817
>
COMPLIANCE INFO_JUN 2016 - 2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/9/2019 4:51:00 PM
Creation date
11/8/2018 9:58:28 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
JUN 2016 - 2018
RECORD_ID
PR0502817
PE
2361
FACILITY_ID
FA0005584
FACILITY_NAME
VALLEY PACIFIC LODI PLANT & CARDLOCK
STREET_NUMBER
930
Direction
E
STREET_NAME
VICTOR
STREET_TYPE
RD
City
LODI
Zip
95240
APN
04905023
CURRENT_STATUS
01
SITE_LOCATION
930 E VICTOR RD
P_LOCATION
02
P_DISTRICT
004
QC Status
Approved
Scanner
KBlackwell
Supplemental fields
FilePath
\MIGRATIONS3\V\VICTOR\930\PR0502817\COMPLIANCE INFO\COMPLIANCE INFO JUN 2016 - PRESENT.PDF
QuestysFileName
COMPLIANCE INFO JUN 2016 - PRESENT
QuestysRecordDate
9/13/2016 6:46:00 PM
QuestysRecordID
3135584
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
93
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITORING <br /> REPORTING <br /> LODI SAN JOAQUIN COUNTY 016-0822 <br /> 30 V CTOR ROAD, ON 7 2016 <br /> Table 1: Sampling Frequency <br /> Wells Semi-Annuall Annual) <br /> -8, MW-9R, -10, MW-11,W MMW-3, MW-6R, MW-7, M , , <br /> MW-13 MW-12, MW-14, MW-1D <br /> All wells will be monitored quarterly for water levels and the presence or thickness of free product. <br /> I Wells will be sampled semi-annually during the first and third quarters. <br /> 3 Wells will be sampled annually during the third quarter. <br /> 2. The Dischargers shall analyze samples according to standard Environmental Protection <br /> Agency (EPA) protocol using the methods shown in Table 2. <br /> 3. Monitoring wells with free product or a visible sheen (if applicable) shall be monitored at a <br /> minimum for product thickness and depth to water. <br /> Table 2: Sampling Methods <br /> Constituent Analytical Method Maximum Detection Limit <br /> Depth to Water Field Readings -- <br /> Total Petroleum 8015M 50 pg/L <br /> Hydrocarbons as Diesel2 <br /> Total Petroleum 8015M 50 pg/L <br /> Hydrocarbons as Gasoline <br /> Benzene 82060B 0.5 /L <br /> Toluene 8260B 0.5 /L <br /> Eth (benzene 82608 0.5 /L <br /> X lenes 8260B 0.5 /L <br /> MTBE 8260B 0.5 /L <br /> TBA 8260B 10 /L <br /> DIPE 8260B 0.5 /L <br /> TAME 82606 0.5 /L <br /> ETBE3 8260B 0.5 /L <br /> Methanol 8260B 100 /L <br /> Ethanol 4 8260B 50 /L <br /> Volatile Organic ComFoundir 8260B 0.5 /L <br /> 'It the maximum practical quantitation limit is exceeded for a non-detectable result, the Discharger shall <br /> provide an explanation in the report text. All concentrations between the Method Detection Limit and the <br /> Practical Quantitation Limit shall be reported as trace. <br /> 2Only MW-61R, MW-8, MW-9R will be sampled for total petroleum hydrocarbons as diesel. <br /> 3Fuel oxygenates including MTBE, TBA, TAME, DIPE, ETBE, ethanol, and methanol shall be analyzed in all <br /> monitoring wells during two monitoring events in the first and third quarters. If results are nondetectable for <br /> both sampling events, no further monitoring for those constituents is required in that well. If a fuel <br /> oxygenate is detected, it shall be added to the monitoring program for the well in which it was detected. <br /> Monitoring wells for which fuel oxygenates requirements have already been met under previous MRP <br /> requirements do not need to be resampled for these analytes under this MRP. <br /> 4 I volatile organic compounds (VOCs)are detected in a fuel oxygenate chromatograph, VOCs shall be <br /> added to the monitoring program for the well in which it was detected. <br />
The URL can be used to link to this page
Your browser does not support the video tag.