Laserfiche WebLink
• • <br /> SAN JOAQUIN COUNTY <br /> w ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax: (209)468-3433 Web:www.sigov.org/ehd <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> NameY <br /> PG&E Stockton Service Center Pacflity nspection <br /> Aadreea: 4040 West Lane, Stockton Date: Sep 18, 2013 <br /> Facty Title: Phone: <br /> Contact: Alex Steele Env. Specialist 209-337-8902 <br /> Inspection <br /> Type: $Routine $Monitoring System Certification 11 Installation EComplaint-ID#: ❑Other. <br /> (Authority HSC <br /> ConseAlex Steele Til Env. Specialist <br /> Consent for. $Inspection C:Sampling $Photos Granted by: <br /> Panel: Veeder-Root TLS-350 Popmg $Pressurized 0Suctton ❑Gravity Prerfill <br /> en $Mechanical ❑Audible/visual <br /> Panel: System: Prevention: <br /> -UST--- 9 - -�� - ---1 ----- - ------- ------- <br /> Product USED OIL DSL 87-octane <br /> Designated ICC Exp. 6-7-14 violations: 7 Ml-Release Detection ❑M2-Release Prevention ❑M3—Both <br /> Operator: Alex Steele Data: <br /> On Site Service ICC Exp. Manufacturer's <br /> Technician: Jose Carrasco Date: 12-27-13 Training: VR: 11-10-13, VMI: 8-9-15 <br /> VIOLATIONS <br /> # Cl I C2 M I Code Section HSC=California Health and Safety Code;CCR=California Cade of Regulations <br /> Cl=Class 1 violation;C2=Class 2 violation',M=Minor violation <br /> File Review <br /> 101 HSC 25284 No permit to operate <br /> 102 HSC 25404.5 Annual operating fees not paid <br /> 103 HSC 25284(a)(3) No written agreement between the person that the operating permit was issued to and the tank operator to <br /> monitor the tanks stem <br /> 104 HSC 25292.2 Current financial responsibility documents not on file with the Environmental Health Department(EHD) <br /> 105 CCR 2711 Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form) <br /> 106 CCR 2632(b) Monitoring Program(Monitoring&Response Plans)is not current or approved by the EHD <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or fails to completely show where monitoring is performed <br /> 108 CCR 2637 Secondary containment:(a)test not performed;(e)test report not submitted within 30 days;(f)test notification <br /> not provided to the EHD at least 48 hours prior to conducting the test <br /> Monitoring equipment certification:(a)not performed annually;(d)test report not submitted within 30 days; <br /> 109 CCR 2638 (e)test notification not provided to the EHD at least 48 hours prior to conducting an installation,repair, <br /> replacement,calibration,or certification <br /> 110 HSC 25291(f) Annual line leak detector test not performed (Mt) <br /> 111 HSC 25284.2 Annual spill containment testing not performed <br /> 112 CCR 2636(f)(4) Annual line tightness test not performed if positive shutdown or fail safe not present (M7) <br /> 113 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br /> 114 CCR 2715(b) Designated operator does not possess a current ICC CA UST System Operator certification <br /> 115 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to (M2) <br /> permit conditions <br /> 116 HSC 25292.5 Enhanced leak detection(ELD)testing not performed on a system located within 1 000'of public well,or <br /> failures not repaired and retested <br /> 117CCR 2661 Permit to repair UST system not obtained O <br /> 118 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring systfttrigifil <br /> 119 HSC 25298(b) Permit to temporarily close UST system not obtained 171 1 IIIIiiitiiiiif own <br /> 120 HSC 25298(c) Permit to close UST system not obtained <br /> On Site Records <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6%years,written <br /> performance claims pertaining to release detection systems for 5 years,or records of repairs,linings,and <br /> 201 CCR 2712(b) upgrades for the life of the tank. Monitoring records include:(1)date and time of all monitoring or sampling; <br /> (2)monitoring equipment calibration and maintenance records;(3)results of any visual observations;(4) <br /> results of sample analysis performed a lab or in the field;(5)logs of all readings of gauges or other monitoring <br /> equipment, round water elevations,or other test results; 6 results of inventory readings and reconciliations <br /> 202 CCR 2712(i) Monitoring plan,response plan,and/or operating permit and all conditions not onsite <br /> Unauthorized release that:(c)did not escape secondary containment and cleaned up within eight hours (M1) <br /> 203 CCR 2650 was not recorded;(e)escaped secondary containment,not cleaned up after eight hours,or a sudden loss of <br /> product was not reported to the EHD within 24 hours <br /> Inspector. Received By: Title: <br /> Garrett Backus (209) 468-2986 SC46 �I 4' C> - <br /> EHD 23-02 Rev 04/19/12 Page 1 UST INSPECTION REPORT <br />