• SAN JOAQUIN COUNTY • <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, Califomia 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www. iggov.org/ehd <br /> UNDERGROUND STORAGE TANK (UST) PROGRAM INSPECTION REPORT <br /> FacilityFacility Inspection <br /> Name: PG&E Addresa: 4040 West Lane, Stockton Date: Sep 28, 2012 <br /> FacilityAlSteele Title: Env. S ecialist Phone: 337-8902 <br /> Alex ee <br /> ContacC p <br /> Inspection XRoufine XMonitomig System Certification 1 i instanation -.1 Complaint—ID# ❑Omer. <br /> Type: <br /> (Authority HSC 25289) Alex Steele Tme: Env. Specialist <br /> Consentfor. Xlnspection I:ISampling XPWos Granted by: <br /> Monitoring Veeder-Root TLS-350 Piping XPressurized OSuction 11Gravity Overfill XMechaniral ❑Audibletvisual <br /> Panel: System: Prevention: <br /> -usT- 9 - 10 - 1� - - - - - -- - - - <br /> Product USED OIL DSL 87-octane <br /> Designated Alex Steele ICC <br /> Ex <br /> Operator. P. 6-7-14 violations: XM1-Release Detection ❑M2-Release Prevention i i M3—Both <br /> On saeSerwce Wes Morrison 'cc Exp 9-29-13 Manufacturer's VR: 6-17-14, VMI: 8-28-14 <br /> Technician: Date: Training: <br /> VIOLATIONS <br /> # I Cl I C2 M I Code Section HSC=California Health and Safety Code;CCR=California Code of RegulaUons <br /> C1=Class 1 dolalioq C2=Class 2 violation;M=Minor Nolstion <br /> File Review <br /> 101 HSC 25284 No permit to operate <br /> 102 HSC 25404.5 Annual operating fees not paid <br /> 103 HSC 25284(a)(3) No written agreement between the person that the operating permit was issued to and the tank operator to <br /> monitor the tank system <br /> 104 HSC 25292.2 Current financial responsibility documents not on file with the Environmental Health Department(EHD) <br /> 105 CCR 2711 Current Unified Program Consolidated Fortes not on file with the EHD(Facility and lank form) <br /> 106 CCR 2632(b) Monitoring Program(Monitoring&Response Plans)is not current or approved by the EHD <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or fails to completely show where monitoring is performed <br /> 108 CCR 2637 Secondary containment:(a)test not performed;(e)test report not submitted within 30 days;(f)test notification <br /> not provided to the EHD at least 48 hours prior to conducting the test <br /> Monitoring equipment certification:(a)not performed annually;(d)test report not submitted within 30 days; <br /> 109 X CCR 2638 (e)test notification not provided to the EHD at least 48 hours prior to conducting an installation,repair, <br /> replacement,calibration,or certification <br /> 110 HSC 25291(f) Annual line leak detector test not performed (Mt) <br /> 111 I I HSC 25284.2 Annual spill containment testing not performed <br /> 112 1 lCCR2636(f)(4) Annual line tightness test not performed if positive shutdown or fail safe not present (M1) <br /> 113 CCR 2715(a) Failed to inform the EHD of a change of designated operator within 30 days <br /> 114 CCR 2715(b) Designated operator does not possess a current ICC CA UST System Operator certification <br /> 115 CCR 2660(k) Repair for tank or piping not tested for tightness after completion of the repair pursuant to (11012) <br /> permit conditions <br /> 116 HSC 25292.5 Enhanced leak detection(ELD)testing not performed on a system located within 1000'of public well,or <br /> failures not repaired and retested <br /> 117 CCR 2681 Permit to repair UST system not obtained <br /> 118 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br /> 119 HSC 25298(b) Permit to temporarily close UST system not obtained <br /> 120 HSC 25298(c) Permit to dose UST system not obtained <br /> On Site Records <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6 h years,written <br /> performance claims pertaining to release detection systems for 5 years,or records of repairs,linings,and <br /> 201X CCR 2712(b) upgrades for the life of the tank. Monitoring records include:(1)date and time of all monitoring or sampling; <br /> (2)monitoring equipment calibration and maintenance records;(3)results of any visual observations;(4) <br /> results of sample analysis performed a lab or in the field;(5)logs of all readings of gauges or other monitoring <br /> equipment,ground water elevations,or other test results; 6 results of inventory readings and reconciliations <br /> 202 CCR 2712(1) Monitoring plan,response plan,and/or operating permit and all conditions not onsite <br /> Unauthorized release that:(c)did not escape secondary containment and cleaned up within eight hours (M1) <br /> 203 CCR 2650 was not recorded;(e)escaped secondary containment,not cleaned up after eight hours,or a sudden loss of <br /> product was not reported to the EHD within 24 hours <br /> 01.Inapadw By: Title: <br /> Garrett Backus (209) 468-2986 � <br /> R , �. S <br /> EHD 23-02 Rev 04/19/12 Page 1 UST INSPECTION REPORT <br />