Laserfiche WebLink
4 . <br /> UNDERGROUND STORAGE TANK <br /> MONITORING PLAN—PAGE 2 <br /> VI.DISPENSER MONITORING <br /> MONITORING OF AREAS BENEATH DISPENSER(S)IS PERFORMED USING THE FOLLOWING METHOD(S)(Check all that apply) M5n. <br /> ® 1.CONTINUOUS ELECTRONIC MONITORING OF UNDER DISPENSER CONTAINMENT(UDC) <br /> PANEL MANUFACTURER: Veeder Root Msl' MODEL#: TLS 350 Mn' <br /> LEAK SENSOR MANUFACTURER: Veeder Root MODEL#(S): 794380-323 M54. <br /> WILL DETECTION OF A LEAK INTO THE UDC TRIGGER AUDIBLE AND VISUAL ALARMS? ® a.YES ❑ b.NO -Mss' <br /> WILL A UDC LEAK ALARM TRIGGER AUTOMATIC PUMP SHUTDOWN? ® a.YES ❑ b.NO M56. <br /> WILL FAILURE/DISCONNECTION OF UDC MONITORING SYSTEM TRIGGER AUTOMATIC PUMP SHUTDOWN? ® a.YES ❑ b.NO M57. <br /> ❑ 2.MECHANICAL ASSEMBLY(e.g.,FLOAT AND 04AIN ASSEMBLY)IN UDC TRIPS SHEAR VALVE IN CASE OF LEAK <br /> ASSEMBLY MANUFACTURER: M58MODEL#(S): Mss' <br /> ❑ 3.VISUAL MONITORING DONE: ❑ a.DAILY ❑ b.WEEKLY(Rega; agc=y appmvn Mho. <br /> ❑ 4.NO DISPENSERS <br /> ❑ 99.OTHER(Specify) M61. <br /> VII. ENHANCED LEAK DETECTION <br /> ❑ 1.WE HAVE BEEN NOTIFIED BY THE STATE WATER RESOURCES CONTROL BOARD THAT WE MUST IMPLEMENT ENHANCED LEAK zrno. <br /> DETECTION(ELD)FOR THE UST(S)COVERED BY THIS PLAN.PER 23 CCR§§2644.1,ELD IS PERFORMED EVERY 36 MONTHS AS REQUIRED <br /> VIII. TRAINING <br /> REFERENCE DOCUMENTS MAINTAINED AT FACILITY(Check all that apply) M80. <br /> 1. ® THIS UNDERGROUND STORAGE TANK MONITORING PLAN(Required) <br /> 2. ® OPERATING MANUALS FOR ELECTRONIC MONITORING EQUIPMENT(Required)' <br /> 3. ® THE FACB,rTY'S BEST MANAGEMENT PRACTICES(Required as of MM/DD/YY) <br /> 4. ❑ CALIFORNIA UNDERGROUND STORAGE TANK REGULATIONS <br /> 5. ❑ CALIFORNIA UNDERGROUND STORAGE TANK LAW <br /> 6. ❑ STATE WATER RESOURCES CONTROL BOARD (SWRCB) PUBLICATION: "HANDBOOK FOR TANK OWNERS - MANUAL AND <br /> STATISTICAL INVENTORY RECONCILIATION" <br /> 7. ❑ SWRCB PUBLICATION:"WEEKLY MANUAL TANK GAUGING FOR SMALL UNDERGROUND STORAGE TANKS" <br /> 99. ❑ OTHER(Specify): Mel. <br /> Personnel with UST monitoring responsibilities are familiar with all of the above documents relevant to theirjob duties and can access those documents when needed. <br /> By 1/1/2005,this facility will have a"Designated UST Operator"who has passed the operator exam adminislered by the International Code Council(ICC). By July 1, <br /> 2005,and annually thereafter,the "Designated UST Operator"will train facility employees in the proper operation and maintenance of the UST systems.This training <br /> will include,but is not limited to,the following: <br /> ➢ Operation of the UST systems in a manner consistent with the facility's best management practices. <br /> ➢ The facility employee's role with regard to the leak detection equipment. <br /> ➢ The facility employee's role with regard to spins and overfills. <br /> ➢ Whom to contact for emergencies and leak detection alarms. <br /> For facility employees hired on or after July 1,2005,the initial training will be conducted within 30 days of the date of hire. <br /> IX. COMMENTS/ADDITIONAL INFORMATION <br /> Please use this section to include any additional UST system monitoring-related information(e.g.,additional information required by your local agency): M85. <br /> *Monitoring systems manual maintained by contracted,licensed pump and tank technicians. <br /> Best Management Practices are maintained in the H.S.S.E.Retail Facility Programs Manual(Green Binder). <br /> *Tank Overfill Protection Type: Over ; I I 61ArM ,alarm visual and audible at tank fill point(s)and operates alarm <br /> trigger at 90%. <br /> X. PERSONNEL RESPONSIBILITIES <br /> THE FACILITY OPERATOR DESIGNATED IN SECTION XI BELOW IS RESPONSIBLE FOR PEFORMING MONITORING. BP WEST COAST PRODUCTS <br /> LLC IS RESPONSIBLE FOR MAINTAINING AND TESTING ALL MONITORING EQUIPMENT. <br /> XI. OWNER/OPERATOR SIGNATURE <br /> CERTIFICATION:I certify that the information provided herein is true and accurate to the best of my knowledge. <br /> OWNER/O ERATOR SIGNATURE REPRESENTING DATE: <br /> ®Owner M90. <br /> ❑Operator <br /> OWNER/OPERATOR NAME(print): M93. OWNER/OPERATOR TITLE: M93. <br /> RUTH HA Environmental Compliance Specialist <br /> (Agency Use Only) This plan has been reviewed and: ❑Approved NApproved With Conditions �i❑Disapproved <br /> Local Agency Signature: ✓ Date: t ,1O <br /> Comments/Special Condition =s off( �I INViP �� ��D�,tt �. VML' T 4t •II,, <br /> Iax <br /> I I UIGV Gn <br /> YV(aaa�(( Vltae55frvy G�Wt�V�. " <br /> Arco#09600,Eelshire Environmental Services Page 2 of I5 <br />