My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2005-2008
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
1250
>
2300 - Underground Storage Tank Program
>
PR0231299
>
COMPLIANCE INFO 2005-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:09 PM
Creation date
11/8/2018 10:00:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2008
RECORD_ID
PR0231299
PE
2361
FACILITY_ID
FA0003972
FACILITY_NAME
THRIFTY OIL COMPANY
STREET_NUMBER
1250
Direction
N
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
11731001
CURRENT_STATUS
02
SITE_LOCATION
1250 N WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\W\WILSON\1250\PR0231299\COMPLIANCE INFO 2005-2008.PDF
QuestysFileName
COMPLIANCE INFO 2005-2008
QuestysRecordDate
5/24/2018 4:59:31 PM
QuestysRecordID
3904191
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
357
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
rWork Order: 2248616 • • <br /> by <br /> Emergency Stop Switch Test <br /> open <br /> Outside Wali <br /> Inside Wall 777- L <br /> Other <br /> Did ESO function correctly(remove 220 from both sides of the relay)? E NO <br /> Test Result (PASS 1 FAIL) �.,4� <br /> lithe test FAILS call the Elite Customer Solutions Center Immediately. <br /> Date!Time 1 Name at Help Desk notified <br /> If the test FAILS teach the site personnel alternative emergency shut down procedure <br /> (e.g.Circuit breakers, pump controller <br /> Date 1 Time 1 Name at employee trained <br /> a system does not tum hack on when the E-Stop is reactivated,the site personell are to contact the BP help Desk. <br /> The Help desk wkl talk them through resetting the E-Stop and or issue a 4 hour contractor response. <br /> Technician Signature l Date C-J <br /> BP E5T0F test Fcrm4ew2007,As <br /> Tanknology Inc.8900 Shoal Creek, Building 200 Austin,Texas 78757 <br />
The URL can be used to link to this page
Your browser does not support the video tag.