My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2005-2008
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
1250
>
2300 - Underground Storage Tank Program
>
PR0231299
>
COMPLIANCE INFO 2005-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:09 PM
Creation date
11/8/2018 10:00:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2008
RECORD_ID
PR0231299
PE
2361
FACILITY_ID
FA0003972
FACILITY_NAME
THRIFTY OIL COMPANY
STREET_NUMBER
1250
Direction
N
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
11731001
CURRENT_STATUS
02
SITE_LOCATION
1250 N WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\W\WILSON\1250\PR0231299\COMPLIANCE INFO 2005-2008.PDF
QuestysFileName
COMPLIANCE INFO 2005-2008
QuestysRecordDate
5/24/2018 4:59:31 PM
QuestysRecordID
3904191
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
357
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
3. Piping Leak Detection Monitoring Equipment <br /> Monitoring Method Manufacturer Model Monitoring Frequency <br /> ® Sump leak sensors connected to <br /> continuous monitoring system Veeder Root 794380-323 <br /> Specify type: Continuous <br /> ❑ Discriminating <br /> ® Non-discriminating <br /> ® Mechanical line leak detectors with Vaporless LD2000 <br /> programmed leak threshold of three Every pumping cycle <br /> allons er hour <br /> El Electronic line leak detectors with <br /> programmed leak threshold of: Every pumping cycle <br /> ❑0.1 qph ❑0.2 gph 03 h <br /> ❑ Line integrity testing by: <br /> ❑ Electronic fine leak detector is <br /> equipped to conduct line tightness ❑Annually <br /> testing ❑ Other: <br /> ❑Third party testing <br /> ® <br /> Notre uired <br /> ❑ Other(Specify): <br /> 4. Dispenser Leak Detection Monitoring Equipment <br /> Monitoring Method Manufacturer Model Monitoring Frequency <br /> ❑ Mechanical float in dispenser <br /> containment Continuous <br /> ® Electronic leak sensor in dispenser <br /> containment: Veeder Root 794380-323 Continuous <br /> El Discriminating <br /> ® Non-discriminating <br /> ❑ Visual inspection ❑ Daily <br /> El Other: <br /> ED] No under-dispenser containment <br /> ❑ Other(specify): <br /> 5. Positive Shutdown Capabilities <br /> ❑ System does not have positive shutdown capabilities <br /> ❑ Individual dispenser shutdown will occur whenever release is sensed in under-dispenser containment <br /> ® Automatic pump shut off will occur whenever: <br /> ® Release is sensed in turbine sump <br /> ❑ Release is sensed in primary piping <br /> ® Release is sensed at dispenser <br /> ® Monitoring system is disconnected or fails in any way(fail safe) <br /> ❑Other(specify): <br /> 6. Secondary Containment Testing <br /> ❑ Secondary containment is not tested <br /> ® In the State of California,secondary containment systems installed on or after January 1,2001,shall be tested upon installation, <br /> six months after installation, and every 36 months thereafter. Secondary containment systems installed prior to January 1, 2001, <br /> shall be tested by January 1,2003, and every 36 months thereafter. <br /> 7. Annual Equipment Certification/restin <br /> ®Annually <br /> ❑ Other(specify): <br /> 2 <br />
The URL can be used to link to this page