My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2005-2008
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
1250
>
2300 - Underground Storage Tank Program
>
PR0231299
>
COMPLIANCE INFO 2005-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:09 PM
Creation date
11/8/2018 10:00:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2008
RECORD_ID
PR0231299
PE
2361
FACILITY_ID
FA0003972
FACILITY_NAME
THRIFTY OIL COMPANY
STREET_NUMBER
1250
Direction
N
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
11731001
CURRENT_STATUS
02
SITE_LOCATION
1250 N WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\W\WILSON\1250\PR0231299\COMPLIANCE INFO 2005-2008.PDF
QuestysFileName
COMPLIANCE INFO 2005-2008
QuestysRecordDate
5/24/2018 4:59:31 PM
QuestysRecordID
3904191
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
357
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Page of <br /> 7. tOER-DISPENSER CONTAINMENT(UO)TESTING <br /> Test Method Developed By: UDC Manufacturer ❑ Industry Standard ® Professional Engineer ❑ <br /> Other(Specify) <br /> Test Method Used: Pressure ❑ Vacuum ❑ Hydrostatic <br /> Other(Specify) <br /> Test Equipment Used: Wayne Perry Inc. See Attached Testing Results Equipment Resolution: .00007 <br /> Under-Dispenser Containment Number Below <br /> UDC Manufacturer: t <br /> UDC Material: <br /> UDC Depth: <br /> Height from UDC Bottom to Top <br /> of Highest Piping Penetration: illl A� <br /> Height from UDC Bottom to <br /> Lowest Electrical Penetration: <br /> Condition of UDC prior to <br /> testing: i <br /> Portion of UDC Tested' 2°Above Highest 2"Above Highest 2"Above Highest 2"Above Highest <br /> Penetration Penetration Penetration Penetration <br /> Does turbine shut down when ❑Yes❑ No NA® ❑ Yes❑ No NA® ❑Yes❑ No NA® ❑Yes❑ No NA® <br /> UDC sensor detects liquid. <br /> Turbine shutdown response time ❑ Yes❑ No NA® ❑Yes❑ No NA® ❑ Yes❑ No NA® ❑Yes❑ No NA® <br /> Is system programmed for fail- <br /> safe shutdown?. [IYes❑ No NAM ❑Yes❑ No NAM [3Yes❑ No NAM [IYes[INo NA® <br /> Was fail-safe verified to be ❑ Yes❑ No NA® ❑Yes❑ No NA® ❑Yes❑ No NAM ❑Yes❑ No NA® <br /> operational?* <br /> Wait time between applying <br /> pressure/vacuum/water and 15 Minutes 15 Minutes 15 Minutes 15 Minutes <br /> starting test <br /> Test Start Time: <br /> Initial Reading(RI): y71 tfy Ivjz92 <br /> Test End Time: Z : 2 Z, /( <br /> Final Reading(RF): <br /> Test Duration: 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min 15 Min <br /> Change in Reading(RF-RD: 214-Op_45— <br /> Pass/Fail <br /> JPass/Fail Threshold or Criteria: -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 -0.0020 <br /> Test Result: [g Pass V Pass ❑ Pass ❑ Pass ❑ Pass ❑ Pass ❑ Pass ❑ Pass <br /> ❑ Fail 1 ❑ Fail ❑ Fail I ❑ Fail ❑ Fail ❑ Fail ❑Fail 1 ❑, Fail <br /> Was sensor removed for testing? ❑ Yes❑ No NA❑ ❑Yes❑ No NAE] ❑ Yes❑ No NA❑ ❑ Yes❑ No NA❑ <br /> Was sensor properly replaced and ❑ Yes❑ No NAE] ❑ Yes❑ No NAE] ❑Yes❑ No NAE] ❑ Yes❑ No NAE] <br /> verified functional after testing? <br /> Comments—(include information on repairs made prior to testing, and recommended fallow-up forfailed tests) <br /> Arco #9600 <br /> 1250 N Wilson Way <br /> Stockton, CA. 95205 <br /> N05114 — SB 989 Testing <br />
The URL can be used to link to this page
Your browser does not support the video tag.