My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2005-2008
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
1250
>
2300 - Underground Storage Tank Program
>
PR0231299
>
COMPLIANCE INFO 2005-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:09 PM
Creation date
11/8/2018 10:00:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2008
RECORD_ID
PR0231299
PE
2361
FACILITY_ID
FA0003972
FACILITY_NAME
THRIFTY OIL COMPANY
STREET_NUMBER
1250
Direction
N
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
11731001
CURRENT_STATUS
02
SITE_LOCATION
1250 N WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\W\WILSON\1250\PR0231299\COMPLIANCE INFO 2005-2008.PDF
QuestysFileName
COMPLIANCE INFO 2005-2008
QuestysRecordDate
5/24/2018 4:59:31 PM
QuestysRecordID
3904191
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
357
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
MONITANG SYSTEM CERTIFICAWN <br /> For Use By All Jurisdictions Within the State of California <br /> Authority Cited.,Chapter 6.7,Health and Safety Code;Chapter 16,Division 3 Title 23,California Code of Regulations <br /> This form must be used to document testing and servicing of monitoring equipment. If more than one monitoring system control panel is installed at the facility,a separate <br /> certification or report must be prepared for each mondorino system control panel by the technician who performs the work. A copy of this form must be provided to the tank <br /> system owner/operator. The owner/operator must submit a copy of this form to the local agency regulating UST systems within 30 days of test date. <br /> A.General Information <br /> Facility Name: ARCO#09600,CC 18022603 City: STOCKTON CA Zip:95205 <br /> Site Address: 1250 N.WILSON WAY Contact Phone No: 465-5359 <br /> Date of Testing/Service: 03/26/2008 <br /> Facility Contact Person: MANAGER <br /> Make/Model of Monitoring System:V.R.TLS-350 Work Order Number: 2255433 <br /> B.Inventory of Equipment Tested/Certified <br /> Check the appropriate boxes to indicate specific equipment inspected/serviced <br /> Tank ID: 1-87 Tank ID: 2-89 <br /> 71 In-Tank Gauging Probe. Model: MAG X1 In-Tank Gauging Probe. Model: MAG <br /> 71 Annular Space or Vault Sensor. Model: 420 21 Annular Space or Vault Sensor. Model: 420 <br /> -71 Piping Sump/Trench Sensor(s). Model: 323 21Piping Sump/Trench Sensor(s). Model: 323 <br /> -71 <br /> Fill Sump Sensor(s). Model: 323 2323 <br /> Fill Sump Sensor(s). Model: <br /> X Mechanical Line Leak Detector. Model: VAPOR LESS(LD-2000) 21 Mechanical Line Leak Detector. Model: VAPOR LESS(LD-2000) <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank Overfill/High-Level Sensor. Model: Tank Overnll/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Tank ID: - TanklD: <br /> 71 In-Tank Gauging Probe. Model: MAG In-Tank Gauging Probe. Model: <br /> X Annular Space or Vault Sensor. Model: 420 Annular Space or Vault Sensor. Model: <br /> X Piping Sumprrrench Sensor(s). Model: 208 Piping Sump/Trench Sensor(s). Model: <br /> X Fill Sump Sensor(s). Model: 208 Fill Sump Sensor(s). Madel: <br /> X Mechanical Line Leak Detector. Model: VAPOR LESS(LD-2000) Mechanical Line Leak Detector. Model: <br /> Electronic Line Leak Detector. Model: Electronic Line Leak Detector. Model: <br /> Tank OverriII/High-Level Sensor. Model: <br /> Tank Overfill/High-Level Sensor. Model: <br /> Other(specify equipment type and model in Section E on page 2). Other(specify equipment type and model in Section E on page 2). <br /> Dispenser : 1/3 Dispenser ID: 4/6 <br /> X❑Dispenser Containment Sensors) Model:323 X Dispenser Containment Sensor(s) Madel:323 <br /> X]Shear Valve(s). -X-1 Shear Valve(s) <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chaln(s). <br /> Dispenser ID: 7/12 Dispenser ID: 13/15 <br /> X1 Dispenser Containment Sensor(s) Model:323 -Xj Dispenser Containment Sensor(s). Model:323 <br /> X] Shear Valve(s). 71 Shear Velvets). <br /> Dispenser Containment Float(s)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> Dispenser ID: 16/18 Dispenser ID: 19/20 <br /> X❑ Dispenser Containment Sensor(s) Model:323 X Dispenser Containment Sensor(s). Model:323 <br /> ❑X Shear Valve(s). X Shear Velvets). <br /> 10 Dispenser Containment Floats)and Chain(s). Dispenser Containment Float(s)and Chain(s). <br /> "If the facility contains more tanks or dispensers,copy this form. Include information for every tank and dispenser at the facility. <br /> C. Certification <br /> I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers'guidelines. <br /> Attached to this certification is information(e.g manufacturers'checklists)necessary to verify that this information is correct. <br /> and a Site Plan showing the layout of monitoring equipment.For any equipment capable of generating such reports,I have also attached <br /> a copy of the(Check all that apply): ❑System set-up X1 Alarm history report <br /> Technician Name(print): JOEY MESA Signature: <br /> Certification No.: A27796 License.No.: <br /> Testing Company Name:Tanknology Phone No.: (800)800-4633 <br /> Site Address: 8501 N.MoPac Expressway,suite 400,Austin,TX 78759 Date of Testing/Servicing: 03/26/2008 <br /> Monitoring System Certification Page 1 of 3 Based on CA form dated 03/01 <br />
The URL can be used to link to this page
Your browser does not support the video tag.