My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2005-2008
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
1250
>
2300 - Underground Storage Tank Program
>
PR0231299
>
COMPLIANCE INFO 2005-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:09 PM
Creation date
11/8/2018 10:00:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2008
RECORD_ID
PR0231299
PE
2361
FACILITY_ID
FA0003972
FACILITY_NAME
THRIFTY OIL COMPANY
STREET_NUMBER
1250
Direction
N
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
11731001
CURRENT_STATUS
02
SITE_LOCATION
1250 N WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\W\WILSON\1250\PR0231299\COMPLIANCE INFO 2005-2008.PDF
QuestysFileName
COMPLIANCE INFO 2005-2008
QuestysRecordDate
5/24/2018 4:59:31 PM
QuestysRecordID
3904191
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
357
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
0 SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 600 East Main Street, Stockton,California 95202-3029 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sigov.orwehd <br /> UNDERGROUND STORAGE TANK UST PROGRAM INSPECTION REPORT <br /> Facility name: Designated Operaator:/ Inspection Date: <br /> Facility address: UST# <br /> `�' -Product 9-7 3'f <br /> Facilit Contact: Title: Phone: <br /> Monitoring Panel: Piping system: Overfill prevention: <br /> pressurized ❑Suction ❑Gravity <br /> ❑Mechanical udiblelvisual <br /> Inspection type: Violations: <br /> patine Anonitoring Certification ❑Installation ❑Other: ❑MI-RDetect 2-RPrev ❑M-3 Both <br /> # Code Section VIOLATION(S) HSC=California Health&Safety Code;CCR=California Code of Regulations V R <br /> V=Violation; RV=Re eat Violation V <br /> I HSC 25284 Permit tooperate <br /> 2 CCR 2637 Secondary containment test Performed <br /> 3 CCR 2711 b)& c Current Unified Program Consolidated Forms on file with EHD(Facility and tank form <br /> 4 HSC 25292.2 Certification of financial responsibility and CFO letter <br /> 5 CCR 2632 6 _Monitoring Program(Monitoring&Response Plan is current and approved by the local agency. <br /> 6 CCR 2712 i Monitoring Ian is onsite. <br /> 7 CCR-2712 6 Maintenance&monitoring records (M l <br /> 8 CCR 2643 d Daily monitoring of suction piping(pre-January, 1, 1984) <br /> 9 HSC 25292.1 UST system isoperated to prevent unauthorized release <br /> 10 CCR 2632(c)(2) UST monitoring system is present Ml <br /> I I CCR 2630 d UST system monitoring equipment is properly located to detect a leak M 1) <br /> 12 HSC 25291 b UST system monitoring equipment isoperational (M2) <br /> 13 CCR 2636(t)(1) Continuous monitoring system for underground piping&UDC is present (M 1) <br /> 14 CCR 2631 a Primary containment is product tight <br /> 15 HSC 25291 (a)(2) Secondary containment for UST is tight <br /> 16 CCR 2636 (c 1) All releases in secondary pipingflow to a collection sum <br /> 17 HSC 25291 Line leak detectors are installed M 1) <br /> 18 CCR 2635(b)(1) Spill container (M2) <br /> 19 CCR 2635(b)(2) Overfill prevention s stem M2) <br /> 20 CCR 2636(a) Conventional suction piping shall have continuous monitoring&20 containment <br /> 21 HSC 25291 (e) Water in 2°containment analyzed&properly disposed of <br /> 22 CCR 2650 Recording/reporting of unauthorized releases (M 1 <br /> 23 CCR 2715 Designated Operator: a)Statement from UST owner; (c-e)Monthly inspection: t)Employee training <br /> 24 CCR 2638 a Annual monitoring certification <br /> 25 CCR 2638(a) Annual line leak detector test (M I) <br /> 26 HSC 25284.2 Annuals ill containment testin <br /> 27 CCR 2636(t)(4) Annual line tightness test (M 1) <br /> 28 CCR 2661 f) Repair for tank/pip ng has had tightness test M2) <br /> 29 CCR 2643 e) Biennial tightness test of gravity piping(pre-January 1, 1984) <br /> 30 CCR 2643 d) Triennial line test for conventional suction piping(pre-January 1, 1984) (M I) <br /> 31 HSC 25292.5 Double walls stem located within 1000'of public well-ELD <br /> 32 CCR 2661 Permit to repair UST system <br /> 33 HSC 25286 a Permit to alter monitoring system <br /> 34 HSC 25298 b) Permit to tem.porari1v close UST system <br /> 35 HSC 25298 c Permit to close UST system <br /> 36 HSC 25299(a)(9) Disabling leak detection devices <br /> 37 HSC 25298 a) Illegal abandonment of UST system <br /> 38 1 Other: <br /> EHD INSPECTORPHONE: UIC <br /> Septic system' <br /> Serves>20 people/day <br /> RECEIVEDB . TITLE: -Receives other than sanitary waste <br /> test Other disposal methods <br /> "�Cas Dry wells/French Drains <br /> EHD 23-02-002 REV 05/07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.