My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2005-2008
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
1250
>
2300 - Underground Storage Tank Program
>
PR0231299
>
COMPLIANCE INFO 2005-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:09 PM
Creation date
11/8/2018 10:00:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2008
RECORD_ID
PR0231299
PE
2361
FACILITY_ID
FA0003972
FACILITY_NAME
THRIFTY OIL COMPANY
STREET_NUMBER
1250
Direction
N
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
11731001
CURRENT_STATUS
02
SITE_LOCATION
1250 N WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\W\WILSON\1250\PR0231299\COMPLIANCE INFO 2005-2008.PDF
QuestysFileName
COMPLIANCE INFO 2005-2008
QuestysRecordDate
5/24/2018 4:59:31 PM
QuestysRecordID
3904191
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
357
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4. TANK ANNULAR TESTING <br /> Test Method Developed By: ❑Tank Manufacturer ® Indust Standard <br /> industry ❑ Professional Engineer <br /> ❑ Other(Sped) <br /> Test Method Used: ❑Pressure 0 Vacuum <br /> ❑Other(Specify) <br /> Test <br /> Test Equipment Used:Test plugs,venturi pump and gauges Equipment Resolution: 0.5%of span <br /> ;, ; •atts€c. ,;a.set :.ara� ,t _ Y�: Iwa-sem --�riait+��rc.n.��a.. :rr, r , <br /> r Tank# Tank#. <br /> Tanlc# Tanlc# <br /> Is Tank Exempt From Testing?' ❑ Yes No ❑ Yes No ❑ Yes C] No <br /> ❑ Yes ❑ No <br /> Tank Capacity; ,sem <br /> Tank Material: 10 , 5 ite'tZi� 5 i t <br /> 'Tank Manufacturer: _� W ' _ <br /> Product Stored: O( ( Q9 <br /> Wait time between applying <br /> pressure/vacuum/water and <br /> startin test: to to rwo <br /> Test Start Time: <br /> Initial Reading(Rj): - 04 a <br /> Test End Time: l bit <br /> a.'3 S Z•y3 5 ;3 S <br /> Final Reading(RF): to d Jt t <br /> O (p <br /> Test Duration: <br /> Change in Reading(1101): L <br /> Pass/Fail Threshold or Criteria: No detectable Loss No detectable Loss Na detectable Loss No detectable Loss <br /> Test Result: Pass ❑Fail Pass ❑ Fail Pass ❑ Fail ❑ Pass ❑Fail <br /> Was sensor removed for testing? 1 91 Yes ❑No ❑NA Yes ❑No ❑NA as ❑No❑NA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced andJ <br /> verified functional after testing? I�Yes ❑No ❑NA 0 Yes ❑No ❑NA yes ❑No❑NA ❑Yes ❑No ❑NA <br /> COMMents—(include information at repairs made prior to testing, and recommended olloty up or failed tests) <br /> Ao-� i ckt res rv�ltj\lr-o LAO . (ZO,�z' -CEAs slOW <br /> is c� <br /> Secondary containment systems where the continuous monitoring automatically monitors both the primaryand secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum,are exempt from periodic containment <br /> testing. {Califomia Code of Regulations,Title 23,Section 2637(a)(6)) <br />
The URL can be used to link to this page
Your browser does not support the video tag.