My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2005-2008
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
1250
>
2300 - Underground Storage Tank Program
>
PR0231299
>
COMPLIANCE INFO 2005-2008
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
7/6/2020 4:40:09 PM
Creation date
11/8/2018 10:00:35 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2005-2008
RECORD_ID
PR0231299
PE
2361
FACILITY_ID
FA0003972
FACILITY_NAME
THRIFTY OIL COMPANY
STREET_NUMBER
1250
Direction
N
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
11731001
CURRENT_STATUS
02
SITE_LOCATION
1250 N WILSON WAY
P_LOCATION
01
P_DISTRICT
001
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\W\WILSON\1250\PR0231299\COMPLIANCE INFO 2005-2008.PDF
QuestysFileName
COMPLIANCE INFO 2005-2008
QuestysRecordDate
5/24/2018 4:59:31 PM
QuestysRecordID
3904191
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
357
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
4• TANK ANNULAR TESTING <br /> Test Method Developed By: ❑Tank Manufacturer ® Industry Standard ❑ Professional Engineer <br /> ❑ Other(Speck) <br /> Test Method Used: ❑pressure ®Vacuum ❑Hydrostatic <br /> ❑Other(Sped) <br /> Test Equipment Used:Test plugs,venturi pump and gauges Equipment Resolution: 0.5%of span <br /> Tank# , .�13--\-- Tank# Tank# -6'3,- Tanlc# <br /> Is Tank Exempt From Testing?' ❑ Yes No ❑ Yes o ❑ Yes No ❑ Yes 0 No <br /> Tank Capacity: (SK 12.E �ZK <br /> Tank Material: <br /> Tank Manufacturer: <br /> i Product Stored: 1l <br /> I <br /> Wait time between applying <br /> pressure/vacuum/water and t lti1 <br /> starting test: <br /> Test Start Time: <br /> Initial Reading(111): <br /> Test End Time: <br /> Final Reading(RF): <br /> Test Duration: <br /> Change in Reading(RF-Rj): <br /> Pass/Fail Threshold or Criteria: No detectable os No detectable xoss No detectableLoss No detectable Loss <br /> Test Result: 0 Pass dFail 0 Pass all Pass dFall 0 Pass 0 Fail <br /> Was sensor removed for testing? A Yes ❑No ❑NA ❑Y s ❑No It Y s ❑No❑NA ❑Yes ❑No ❑NA <br /> Was sensor properly replaced and yes ❑No ❑NA .Yes ❑No ❑NA Yes ❑No❑NA ❑Yes ❑No ❑NA <br /> verified functional after testin ? <br /> Comments—(include information on repairs made prior to testing, and recommended follow-up for jailed tests) <br /> 1S r% c.� rnpa,�r .�..�,—?r�T CCu�X4.rv1 L"LlnnW4 <br /> l <br /> Secondary containment systems where the continuous monitoring automatically monitors both the primary and secondary <br /> containment,such as systems that are hydrostatically monitored or under constant vacuum, are exempt from periodic containment <br /> testing. (California Code of Regulations,Title 23,Section 2637(a)(6)1 <br />