x! 11 01 ` <br /> SWRCB,January 2002 NVi 1ViPlNTA <br /> 5. SECONDARY PIPE TESTING — — --- -- — <br /> Test Method Developed By: X Piping Manufacturer C Industry Standard C Professional Engineer <br /> C Other(Spec) <br /> Test Method Used: X Pressure C Vacuum C Hydrostatic <br /> C Other(Spec) <br /> Test Equipment Used:Pressure Gauges in Psi/Nitrogen Equipment Resolution: 1/10-15 Psi <br /> Piping Run#t Piping Run#2 Piping Run# Piping Run# <br /> Piping Material: Fiberglass Fiberglass <br /> Piping Manufacturer: Ameron Ameron <br /> Piping Diameter: 3" 3" <br /> Length of Piping Run: 40' 50' <br /> Product Stored: Regular 87 Super 91 <br /> Method and location of Test boot at STP Test boot at STP <br /> piping-run isolation: Piping Sump#1 Piping Sump 92 <br /> Wait time between applying 10 Minutes 10 Minutes <br /> ressure and startingtest: <br /> Test Start Time: 9:35 9:45 <br /> Initial Reading(Ri): 3.2 Psi 3.2 Psi <br /> Test End Time: 10:35 10:45 <br /> Final Reading(RF): 3.2 Psi 3.2 Psi <br /> Test Duration: 1 Hour 1 Hour <br /> Change in Reading(RP-Ri): 0 Psi 0 Psi <br /> Pass/Fail Threshold or No Loss in Psi - No Loss in Psi <br /> Criteria: <br /> Test Result: Pass Pass <br /> Comments— (include information on repairs made prior to testing and recommended follow-up far failed tests) <br />