My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
1756
>
2300 - Underground Storage Tank Program
>
PR0231300
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/31/2019 11:51:39 AM
Creation date
11/8/2018 10:01:04 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231300
PE
2361
FACILITY_ID
FA0001858
FACILITY_NAME
MY MINI MART
STREET_NUMBER
1756
Direction
N
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
11721005
CURRENT_STATUS
01
SITE_LOCATION
1756 N WILSON WAY
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\W\WILSON\1756\PR0231300\COMPLIANCE INFO 2013-2016.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
216
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
D. Results of Testing/Servicing <br /> Software Version Installed: 1.11 <br /> :om late the foliowin checklist: <br /> ® Yes ❑ No` Is the audible alarm operational? <br /> ® Yes ❑ No' Is the visual alarm operational? <br /> ® Yes ❑ No' Were all sensors visually inspected,functionally tested,and confirmed operational? <br /> ® Yes ❑ No` Were all sensors installed at lowest point of secondary containment and positioned so that other equipment will not interfere with their proper <br /> operatlon? <br /> ❑ Yes ❑ No` If alarms are relayed to a remote monitoring station,is all communications equipment(e.g.,modem)operational? <br /> 19 N/A <br /> ® Yes ❑ No' For pressurized piping systems,does the turbine automatically shut down if the piping secondary containment monitoring system detects a <br /> ❑ N/A leak, fails to operate, or is electrically disconnected? If yes: -which sensors initiate positive shut-down? (Check all that apply) <br /> Sump/Trench Sensors; ❑Dispenser Containment Sensors. <br /> Did you confirm positive shut-down due to leaks and sensor failureldisconnection? ®Yes; ❑No. <br /> ❑ Yes ❑ No` For tank systems that utilize the monitoring system as the primary tank overfill warning device(i.e.,no mechanical overall prevention valve is <br /> ® N/A installed), is the overfill warning alarm visible and audible at the tank fill point(s) and operating properly? If so, at what percent of tank <br /> capacity does the alarm trigger? 0% <br /> ❑ Yes' ® No Was any monitoring equipment replaced? If yes, identify specific sensors, probes,or other equipment replaced and list the manufacturer <br /> name and model for all replacement parts in Section E,below. <br /> ❑ Yes' ® No Was liquid found inside any secondary containment systems designed as dry systems? (Check all that apply) <br /> ❑Product; ❑Water. If yes,describe causes in Section E,below. <br /> ® Yes ❑ No* Was monitoring system set-up reviewed to ensure proper settings?Attach set up reports,if applicable <br /> ® Yes ❑ No' Is all monitoring equipment operational per manufacturer's specifications? <br /> In Section E below,describe how and when these deficiencies were or will be corrected. <br /> E. Comments: <br /> ALL PASSED INSPECTOR ELENA ON SITE . INCON HAD NO ALARM HIST WHEN I SHOWED UP . HAD TO <br /> ADJUST 87 LD THEN PASSED . ADDED 90 DEGREE BUSHINGS TO SNAP TAPS DUE TO NEW DISPENSERS. <br /> ALSO WHEN I SHOWED UP, ALL SHEAR VALVES WERE WIRED SHUT. ELENA TOOK PICTURES AND I <br /> REMOVED ALL WIRES OFF SHEARS . <br /> Monitoring System Certification Page 2 of 4 11,07 <br />
The URL can be used to link to this page
Your browser does not support the video tag.