My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2013-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
W
>
WILSON
>
1756
>
2300 - Underground Storage Tank Program
>
PR0231300
>
COMPLIANCE INFO_2013-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/31/2019 11:51:39 AM
Creation date
11/8/2018 10:01:04 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2013-2018
RECORD_ID
PR0231300
PE
2361
FACILITY_ID
FA0001858
FACILITY_NAME
MY MINI MART
STREET_NUMBER
1756
Direction
N
STREET_NAME
WILSON
STREET_TYPE
WAY
City
STOCKTON
Zip
95205
APN
11721005
CURRENT_STATUS
01
SITE_LOCATION
1756 N WILSON WAY
P_LOCATION
01
P_DISTRICT
002
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\W\WILSON\1756\PR0231300\COMPLIANCE INFO 2013-2016.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
216
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
i 6 <br /> SAN JOAQUIN COUNTY <br /> ENVIRONMENTAL HEALTH DEPARTMENT <br /> 1868 East Hazelton Avenue, Stockton, California 95205-6232 <br /> Telephone:(209)468-3420 Fax:(209)468-3433 Web:www.sFaov.org/ehd <br /> UNDERGROUND STORAGE TANK(UST) PROGRAM INSPECTION REPORT <br /> Facility M Mini Mart <br /> Facility 1756 N. Wilson., Stockton, CA Ire°" <br /> Name: y Address: Date: Jun 25, 2013 <br /> Facility <br /> Contact Joginder Lal Title: Owner Phone: 337-8669 <br /> Inspection XRoutine XMonitoring System Certification Illnstallation ❑Complaint-IDN: ❑Other. <br /> Type: <br /> (Authority HSC 25289) ��,, <br /> Consenafor. glnspection ;(Sampling g(Photos Granted by:Rajvinder K Sidhu Title: Manapr CabV7,rlea' <br /> Panel System:INCON TS-1001 piping $Pressunzed USucfion oGmvi Overfill <br /> System: ty Prevention: 3(Mechaniral ❑AudIblONtsual <br /> UST 3 4 <br /> --Product 87octans 91-octane --_-.-_-_ ----------------------------- ___________ _ _ _ __._ -_-____ <br /> Designated ICC Exp. <br /> Operator Mark R. Fairbanks Data. 9-29-2013 Violations: XM1-Release Detection oM2-Release Prevention oM3-Both <br /> Tech�� Dave Winkler pateE p 3-5-2014 Tramming: VR:2-13-2014 VMI:11-10-2013 <br /> VIOLATIONS <br /> 9 C1 C2 M I Code Section I HSC=Ca Tania Health and Safety Code;CCR=California Code of Regulations <br /> C1=Class 1 violation;C2=Class 2 violation:M=Mina violation <br /> File Review <br /> 101 HSC 25284 No permit to operate <br /> 102 HSC 25404.5 Annual operating fees not paid <br /> 103 HSC 25284(a)(3) No written agreement between the person that the operating permit was issued to and the tank operator to <br /> monitor the tank system <br /> 104 X HSC 25292.2 Current financial responsibility documents not on file with the Environmental Health Department(EHD) <br /> 105 CCR 2711 Current Unified Program Consolidated Forms not on file with the EHD(Facility and tank form) <br /> 106 X CCR 2632(b) Monitoring Program(Monitoring&Response Plans)is not current or approved by the EHD <br /> 107 CCR 2632(d)(1)(C) Plot plan/site map not submitted or fails to completely show where monitoring is performed <br /> 108 CCR 2637 Secondary containment:(a)test not perforated;(e)test report not submitted within 30 days;(f)test notification <br /> not provided to the EHO at least 48 hours prior to conducting the test <br /> Monitoring equipment certification:(a)not performed annually;(d)test report not submitted within 30 days; <br /> 109 CCR 2638 (e)test notification not provided to the EHD at least 48 hours prior to conducting an installation,repair, <br /> replacement,calibration,or certification <br /> 110 HSC 25291(0 Annual line leak detector test not performed (M1) <br /> 111 HSC 25284.2 Annual spill containment testing not performed <br /> 112 CCR 2636M(4) Annual line tightness test not performed it positive shutdown or fail safe not present IMI) <br /> 113 CCR 2715(x) Failed to inform the EHD of a change of designated operator within 30 days <br /> 114 CCR 2715(b) Designated operator does not possess a current ICC CA UST System Operator certification <br /> 115 CCR 2660(k) Repair for tank or piping not tested for lightness after completion of the repair pursuant to (1112) <br /> permit conditions <br /> 116 HSC 25292.5 Enhanced leak detection(ELD)testing not performed on a system located within 1000'of public well,or <br /> failures not repaired and retested <br /> 117CCR 2661 Permit to repair UST system not obtained <br /> 118 HSC 25286(a) Operational permit not amended when UST storage and/or monitoring system changed <br /> 119 H§g 25299 P@fmit t9 t@mpgrpflly E193E UPT 3 t@ln not 01@In@d <br /> 120 HOU 18290(E) r@fmit to dam U5fi @y§10M not WOW <br /> On Site Records <br /> Maintenance&monitoring records not maintained 3 years,cathodic protection records for 6 54 years,written <br /> performance daims pertaining to release detection systems for 5 years,or records of repairs,linings,and <br /> 201 X CCR 2712(b) upgrades for the life of the tank. Monitoring records include:(1)date and time of all monitoring or sampling; <br /> (2)monitoring equipment calibration and maintenance records;(3)results of any visual observations;(4) <br /> resutls of sample analysis performed a lab or in the field;(5)logs of all readings of gauges or other monitoring <br /> equipment,ground water elevations,or other test results; 6 results of inventory readings and reconciliations <br /> 202 CCR 2712() Monitoring plan,response plan,and/or operating permit and all conditions not onsite <br /> Unauthorized release that:(c)did not escape secondary containment and cleaned up within eight hours (M7) <br /> 203 CCR 2650 was not recorded;(e)escaped secondary containment,not cleaned up after eight hours,or a sudden loss of <br /> product was not reported to the EHD within 24 hours <br /> Inepedor Receiwtlay: Title: <br /> I � 'dGL� 5 icJY <br /> EHD 23-02 Rev 04/19/12 Page 1 UST INSPECTION REPORT <br />
The URL can be used to link to this page
Your browser does not support the video tag.