Laserfiche WebLink
LHL <br /> GROUP INC. ARCHITECTURE a ENGINEERING • ENVIRONMENTAL SERVICES <br /> 650 Howe Ave., Suite 504, Sacramento, CA 95825-4732 Telephone: (916) 646-4003 Facsimile: (916) 646-4679 <br /> JOHN W. JOHNSON November 24, 1998 Established 1966 <br /> Architect <br /> Ca-President Hand Delivered <br /> (209)468-3444 <br /> BRIAN F. z I T A Mr.Michael Kith <br /> Architect San Joaquin County Public Health Services <br /> Ca-Presideat Environmental Health Division <br /> East Weber Street,Third floor <br /> Stockton, <br /> RECEIVED <br /> Stockton, CA 95201-0388 <br /> JOHN B. HICKS <br /> Architect RE: ADDENDUM TO INSTALLATION PERMIT <br /> Vice President .S'OUt nd 7-Eleven Store No. 17647 ENVIRONMENTAL- HEALTH <br /> 1048 est Yosemite Avenue PERMIT/SrL VICES <br /> Manteca, California <br /> CECIL R. SPENCER RHL Job No. 3026.20 <br /> Architect % IS <br /> Vice President Dear W.Kith: <br /> On behalf of the Southland Corporation we submit this letter and the enclosed documents as <br /> ALAN S H I M A B U K U R O an addendum to the permit to install underground storage tanks at the above referenced site. <br /> Regional Manager Per our recent conversation we would like to change the brand of underground storage tanks <br /> Associate from Total Containment to Fluid Containment. The following information for the Fluid <br /> Containment Tanks is enclosed for your review and approval. <br /> • 3 revised sets of plans (1 wet stamped/signed). All changes associated with the Fluid <br /> CHRIS L A W T O N <br /> Regional Manager Containment Tanks are clouded and marked with Delta No. 7 dated 11/20/98. <br /> Associate • New CWRCBForm Aand B's. <br /> • 3 copies of the new tank, sump, interstitial monitor, and line leak detector equipment <br /> specification sheets. <br /> JAMES E. PRESTEN <br /> • Banks & Company's Certificate to Install Fiberglass Underground Tanks. (Owens- <br /> Regional Manager Coming is now doing business as Fluid Containment) <br /> Associate • Fluid Containment's Underground Storage Tank Installation Instruction booklet. <br /> • Tank Buoyancy Calculations. <br /> GARY M. S E M L I N G Changes to the application form are as follows: <br /> Managing Arahisect <br /> Associate Page 5, No. 12 <br /> Tank Manufacturer: Fluid Containment <br /> Composition: Fiberglass <br /> Model: DWT6 <br /> BLYTHE R. WILSON <br /> Managing Architect Corrosion Protection: FRP <br /> Associate <br /> Page 5, No. 13, B. <br /> Fiberglass, (1)Installation instructions require an air test and soap bubble test prior <br /> to installation. <br /> BELLEVUE, WA LA IJAN'RA, CA PETALUMA. CA SCOTTSDALE. AZ <br /> f <br />