Laserfiche WebLink
06/17/1998 17:38 209-825-4251 B/W INN OF MANTECA <br /> •' •' • PAGE 06 <br /> UST SYSTEM DRAWING INFORMATION • <br /> 1• Three complete sets of plans (include manufacturer's specification sheets for proposed equipment to be inatalled). <br /> 2• ,_ Plum drawn to stele in non-erasable print. <br /> 3• Plot plan to show location of tanks and all associated piping. <br /> A• Striker plates or drop tube-mounted bottom protectors illustrated below all accessible openings. <br /> S. Tank cross-sectional diagram. <br /> 6. OetaiL of tank, associated piping, excavation and cover. <br /> 7• Tank(s) and piping approved by a nationally recognized independent testi <br /> Article 3, Section 2631 (b) A 263SJ ng organization. (Title 23, Chapter 16, <br /> a- verification of product compatibility with the tank(s), i in <br /> device(s), epoxy or silicone glues, etc. P P g, monitoring <br /> 9• Manufacturer's written installation instructions for tank(s), Piping, monitoring devices, etc. <br /> 10. At the installation site, <br /> ° prior to installation, a tightness test shell be performed on both primary (1°) and <br /> secondary (2 ) contei rnent syatmm before covering. (Section 2635 (e) (3) s (4)1 <br /> 11. Tank integrity test r uired u n e <br /> reqDo anlesion of installation with tank in operating condition. Test results to be <br /> submitted directly to PHS-END from the testing conpany or owner of facility. <br /> Chapter 6.7, Section 25291 (h)3 (Health 8 Safety Code, Division 20, <br /> 12. TAY[ COYM)SITIOI <br /> TANK 0 s s Y 1 s <br /> CAPACITY <br /> MANUFACTURER <br /> COMPOSITION <br /> MODEL <br /> PRODUCT <br /> CORROSION PROTECTION <br /> U.L. LISTED <br /> COMPATIBILITY WITH 100Z <br /> 14ETRAMOL <br /> 13. TAW(a) TO BE INSTALLED <br /> A. Steel-Clad with fiberglags reinforced plastic coatings, coiposites, or equivalent non-metallic exterior <br /> coatings or coverings. <br /> (1) Tested at the installation site using an electric resistance holiday detector. <br /> (2) Vacuum applied to interstitial space. <br /> g. Fiberglass <br /> (1) installation instructions require an air test and soap bubble test prior to installation. <br /> _- (2) VNCUam applied to interstitia( space. <br /> (3) Hydrostatic annular (pri mery tank pressure test). <br /> C. Non-clad steel tank [Section 2635 (a) (2) (A)J <br /> (1) Cathodic protection provided for entire tank, piping and components (nuts, Its, washers, <br /> etc.)- <br /> _ (2) Field installed cathodic protection systems designed and certified as adequate by a <br /> corrosion specialist. <br /> (3) Impressed current systema to be inspected no less Chan every 60 days. <br /> S <br /> JUN-17-1998 17:21 209 825 4251 95% P.06 <br />