My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO_2016-2018
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
1434
>
2300 - Underground Storage Tank Program
>
PR0231465
>
COMPLIANCE INFO_2016-2018
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
10/13/2023 3:02:39 PM
Creation date
11/8/2018 10:02:44 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2016-2018
RECORD_ID
PR0231465
PE
2361
FACILITY_ID
FA0003739
STREET_NUMBER
1434
Direction
W
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95337
CURRENT_STATUS
01
SITE_LOCATION
1434 W Yosemite Ave
P_LOCATION
04
P_DISTRICT
005
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\Y\YOSEMITE\1434\PR0231465\COMPLIANCE INFO 2016-PRESENT .PDF
QuestysFileName
COMPLIANCE INFO 2016-PRESENT
QuestysRecordDate
6/26/2017 3:55:48 PM
QuestysRecordID
3465141
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
160
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
Underground Storage Tank Program Inspection Report <br />Date: <br />December 06, 2017 <br /> Facility Address: <br /> 1434 W Yosemite Ave, Manteca <br /> Facility Name: <br /> Colonial Energy CE 40134 (DBA Power Mart) <br />San Joaquin County <br />Environmental Health Department <br />1868 East Hazelton Avenue, Stockton, California 95205-6232 <br />Telephone: (209) 468-3420 Fax: (209) 468-3433 Web: www.sjgov.org/ehd <br />SUMMARY OF VIOLATIONS <br />(CLASS I, CLASS II, or MINOR - Notice to Comply) <br />RemarksItem # <br /> 209 CCR 2715(c) Designated operator did not inspect all required items and/or the inspection reports not completed. <br />The designated operator (DO)-Ryan Monte- failed to document all the alarms from the attached alarm history on the <br />1/29/2017 and 2/28/2017 designated operator monthly inspection report and failed to check that they were <br />responded to appropriately. <br />The missing alarms include: <br /> 1/9/2017: an L1 Super Sump STP SUMP fuel alarm occurred <br /> 2/9/2017: an L5 Reg Sump STP SUMP fuel alarm occurred <br /> During the monthly inspection, the designated operator shall review the alarm history for the previous month, <br />check that each alarm was documented and responded to appropriately, and attach a copy of the alarm history with <br />documentation taken in response to any alarms to the monthly report. Ensure that designated operators performing <br />monthly inspections at this facility are including all of the required information on the reports. <br />The designated operator failed to check and note the correct test dates for the secondary containment testing on <br />the December 2016, January 2017, February 2017, March 2017, April 2017, May 2017 and June 2016 designated <br />operator monthly inspection report. The date when the secondary containment test was completed was 8/3/2017. <br />The DO (Ryan Monte) noted it was 12/15/14. During the monthly inspection, the designated operator shall check <br />that all required testing and maintenance for the UST system have been completed and document the dates they <br />were done. Ensure that designated operators performing monthly inspections at this facility are including all of the <br />required information on the reports. <br />The designated operator (Moglesby) failed to visually inspect the spill containers for leaks, water, or debris during <br />the 7/17/2017 monthly inspection. During the monthly inspection, the designated operator shall visually inspect all <br />spill containers and UDC sumps, and any tank top sump that had an alarm for which there is no record of a service <br />visit. Ensure that designated operators performing monthly inspections at this facility are inspecting all of the <br />required areas and noting it on the on the reports. <br />This is a repeat violation, Class II. <br /> 315 HSC 25291(e) Water in secondary containment not removed, analyzed, and properly disposed of (pre-Jul 2003). <br />Liquid was observed in the 87 grade and 91 grade fill sump. If water could enter into the secondary containment by <br />precipitation or infiltration, it must be removed and disposed of properly. The service technician removed 1.5 <br />gallons of liquid from the 87 fill sump and 1.5 gallons of liquid from the 91 grade sump. Ensure that all sumps and <br />annular spaces are maintained free of liquid. <br />This was corrected on site. <br />This is a minor violation. <br /> 318 CCR 2636(f)(2) Leak detector failed to detect a 3.0 gph leak at 10 psi. <br />The 89 grade line leak detector failed to detect a leak when tested. All line leak detectors shall be capable of <br />detecting a 3-gallon per hour leak at 10 psi. The leak detector was replaced and retested during the inspection. A <br />“UST Retrofit Verification with Inspector Already Onsite” form has been completed and provided to the operator and <br />contractor. <br />This is a repeat violation, Class II. <br />Page 5 of 6 <br />FA0003739 PR0231465 SC002 12/06/2017 <br />EHD 23-01 Rev. 09/22/16 Underground Storage Tank Program OIR