Laserfiche WebLink
I I.rt,V <br /> PRODUCT CODE 2 <br /> THERMAL COEFF : .000700 <br /> �./ TANK DIAMETER : 120.00 <br /> TANK PROFILE : 20 PTS <br /> FULL VOL : 5001 <br /> 114.0 INCH VOL : 4905 <br /> 108.0 INCH VOL : 4737 <br /> OUTPUT RELAY SETUP 102.0 INCH VOL : 4526 <br /> - _ - - - - - - - - - - 96.0 INCH VOL : 4284 <br /> 90.0 INCH VOL : 4018 <br /> R I :REGULAR SOUTH IOK 84.0 INCH VOL : 3734 <br /> TYPE: 76.0 INCH VOL : 3436 <br /> STANDARD 72.0 INCH VOL : 3129 <br /> NORMALLY CLOSED 66.0 INCH VOL : 2814 <br /> LIQUID SENSOR SETUPNC <br /> 60.0 IH VOL : 2497 <br /> LIQUID SENSOR ALMS - - - - - - - - _ _ _ 54.0 INCH VOL : 2179 <br /> L 2:FUEL ALARM 48.0 INCH VOL : 1865 <br /> L 5:FUEL ALARM L "ANNULAR 42.0 INCH VOL : 1557 <br /> L 6:FUEL ALARM TRI-STATE 36.0 INCH VOL : 1260 <br /> L 7:FUEL ALARM CATEGORY : ANNULAR SPACE 30.0 INCH VOL : 976 <br /> L B:FUEL ALARM 24.0 INCH VOL : 711 <br /> L 2:SENSOR OUT ALARM 19.0 INCH VOL : 470 <br /> L 5:SENSOR OUT ALARM 12.0 INCH VOL : 260 <br /> L 6:SENSOR OUT ALARM L 2:REGULAR SOUTH IOK 6.0 INCH VOL : 93 <br /> L 7:SENSOR OUT ALARM TRI-STATE <br /> L B:SENSOR OUT ALARM CATEGORY : STP SUMP <br /> L 2:SHORT ALARM FLOAT SIZE: 4.0 INCHES <br /> L 5:SHORT ALARM <br /> L 6:SHORT ALARM L 3:REGULAR MIDDLE 5K WATER WARNING 1 .5 <br /> L 7:SHORT ALARM TRI-STATE HIGH WATER LIMIT: 1 .5 <br /> L B:SHORT ALARM CATEGORY : STP SUMP <br /> MAX OR LABEL VOL: 5001 <br /> R 2-REG MIDDLE 5K OVERFILL LIMIT 904 <br /> TYPE: L 4-DIESEL 4500 <br /> STANDARD TRI-STATE HIGH LEVEL LIMIT: 95'. <br /> NORMALLY CLOSED CATEGORY : STP SUMP 4750 <br /> LIQUID SENSOR ALMS DELIVERY LIMIT 5 <br /> L 3:FUEL ALARM L S:DISP 3-4 2500 <br /> L 5:FUEL ALARM TRI-STATE LOW LEVEL LIMIT 250 <br /> L 6:FUEL ALARM CATEGORY : DISPENSER PAN LEAK ALARM LIMIT: 50 <br /> L 7:FUEL ALARM SUDDEN LOSS LIMIT: 50 <br /> L B:FUEL ALARM TANK TILT 0.00 <br /> L 3:SENSOR OUT ALARM <br /> L 5:SENSOR OUT ALARM L 6:DISP 1-2 MANIFOLDED TANKS <br /> L 6:SENSOR OUT ALARM TRI-STATE TO: NONE <br /> L 7:SENSOR OUT ALARM CATEGORY : DISPENSER PAN <br /> L B:SENSOR OUT ALARM LEAK MIN ANNUAL 500 <br /> L 3:SHORT ALARM <br /> L 5:SHORT ALARM PERIODIC TEST TYPE <br /> L 6:SHORT ALARM L 7:DISP 7-8 STANDARD <br /> L ?:SHORT ALARM TRI-STATE <br /> L B:SHORT ALARM CATEGORY : DISPENSER PAN ANNUAL TEST FAIL <br /> R 3:DIESEL ALARM DISABLED <br /> TYPE: PERIODIC TEST FAIL <br /> STANDARD L 8:DISP 5-6 ALARM DISABLED <br /> NORMALLY CLOSED TRI-STATE <br /> LIQUID SENSOR ALMS CATEGORY : DISPENSER PAN GROSS TEST FAIL <br /> L 4:FUEL ALARM <br /> ALARM DISABLED <br /> L 5:FUEL ALARM ANN TEST AVERAGING: OFF <br /> L 6:FUEL ALARM PER TEST AVERAGING: OFF <br /> L 7:FUEL ALARM _ <br /> L B:FUEL ALARM TANK TEST NOTIFY: OFF <br /> L 4:SENSOR OUT ALARM <br /> L S:SENSOR OUT ALARM TNK TST SIPHON BREAK:OFF <br /> L 6:SENSOR OUT ALARM <br /> L 7:SENSOR OUT ALARM DELIVERY DELAY 5 MIN <br /> L B:SENSOR OUT ALARM <br /> L 4:SHORT ALARM - <br /> L 5:SHORT ALARM - - <br /> L 6:SHORT ALARM <br /> L 7:SHORT ALARM <br /> L B:SHORT ALARM <br /> R 4: <br /> TYPE: <br /> STANDARD <br /> NORMALLY OPEN <br /> NO ALARM ASSIGNMENTS - <br />