My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 1985-2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
853
>
2300 - Underground Storage Tank Program
>
PR0231460
>
COMPLIANCE INFO 1985-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/24/2024 2:52:58 PM
Creation date
11/8/2018 10:04:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985-2006
RECORD_ID
PR0231460
PE
2381
FACILITY_ID
FA0001369
FACILITY_NAME
7-ELEVEN INC. STORE #21756
STREET_NUMBER
853
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95336
CURRENT_STATUS
02
SITE_LOCATION
853 E Yosemite Ave
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\Y\YOSEMITE\853\PR0231460\COMPLIANCE INFO 1985-2006.PDF
QuestysFileName
COMPLIANCE INFO 1985-2006
QuestysRecordDate
8/10/2017 4:54:42 PM
QuestysRecordID
3567749
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
342
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
• California Edition:August, 1996 <br /> Tidel Engineering <br /> EMS-3500 <br /> Liquid Discriminatory Probes Part 301-0635 <br /> LIQUID-PHASE INTERSTITIAL DETECTOR <br /> Detector: <br /> Output type: qualitative <br /> Sampling frequency: continuous <br /> Operating principle: electrical conductivity/hydrocarbon sensitive polymer <br /> Test Results : <br /> Commercial <br /> Gasoline Water. <br /> Accuracy (%) 100 100 <br /> Response time (min) 3.59 0.96 <br /> Recovery time (min) 13.18 <1 <br /> Product activation height (cm) 1.76 0.49 <br /> Lower detection limit 4.19 1.52 <br /> at a now rate of 0.04 gal/hr in a 2.54 cm diameter test chamber <br /> Specificity Results: <br /> Activated: diesel fuel (at liquid height of 1.78 cm), synthetic fuel (at 2.30 cm), home heating oil k (at 2.30 cm). <br /> Manufacturers Specifications: NONE <br /> Comments: <br /> The test procedures used were those in Carnegie Mellon Research Institute's "Test Procedures for Third <br /> Party Evaluation of Leak Detection Methods: Point Sensor Liquid Contact Leak Detection Systems": Final <br /> Report- November 11, 1991. <br /> Tidel Engineering Evaluator. Carnegie Mellon Research Institute <br /> 2615 East Belt Line Road— <br /> Carrollton, TX 75006 <br /> Tel: (800) 676-7577 Date of Evaluation: 01/29/93 <br /> 172 <br /> Appearance on this list is not to be construed as an endorsement by any regulatory agency nor is it any guarantee of the performance of the J <br /> method or equipment. i <br /> 41 `�' i, 03 <br />
The URL can be used to link to this page
Your browser does not support the video tag.