COMPLIANCE INFO 1985-2006
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
Y
>
YOSEMITE
>
853
>
2300 - Underground Storage Tank Program
>
PR0231460
>
COMPLIANCE INFO 1985-2006
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/24/2024 2:52:58 PM
Creation date
11/8/2018 10:04:10 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
1985-2006
RECORD_ID
PR0231460
PE
2381
FACILITY_ID
FA0001369
FACILITY_NAME
7-ELEVEN INC. STORE #21756
STREET_NUMBER
853
Direction
E
STREET_NAME
YOSEMITE
STREET_TYPE
Ave
City
Manteca
Zip
95336
CURRENT_STATUS
02
SITE_LOCATION
853 E Yosemite Ave
P_LOCATION
04
P_DISTRICT
003
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\Y\YOSEMITE\853\PR0231460\COMPLIANCE INFO 1985-2006.PDF
QuestysFileName
COMPLIANCE INFO 1985-2006
QuestysRecordDate
8/10/2017 4:54:42 PM
QuestysRecordID
3567749
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
342
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
a� , • <br /> California Edition:August,7956 - <br /> Vaporless Manufacturing <br /> Vaporless LD 2000E& LD 2000ES <br /> AUTOMATIC MECHANICAL LINE LEAK DETECTOR <br /> Certification: Leak rate of 3.0 gph with PD=100% and PFA=O%. <br /> Leak Threshold: 2.0 gph (a leak is declared if the output of the measurement system exceeds this <br /> threshold). <br /> Applicability: Gasoline,diesel, aviation fuel and solvent. <br /> Specification: System is installed on Flexible piping. <br /> The piping system volume must not exceed 59.6 gallons. 'T'OF <br /> Tests are conducted at the line operating pressure. pE2oD�G'1 L.146 <br /> Waiting Time: There is no waiting period between last dispensing and testing. <br /> There is no waiting period between product delivery and testing. <br /> Test Period: The minimum test time (response time) is 30 seconds. <br /> System Features: This system is permanently installed on the piping and automatically tests the line. <br /> It uses a preset threshold and a single test to determine whether the piping is leaking. <br /> If a leak is detected, the LD 2000E will restrict fuel flow to dispenser, and the LD <br /> 2000E-S will shut off the pump. <br /> Calibration: Equipment must be checked annually for capability of detecting a line leak of 3.0 gph. <br /> Comments: Enviroflex piping with a bulk modulus of 1,352 was used during the third-party <br /> evaluation. <br /> Vaporless Manufacturing Evaluator. Ken Wilcox Associates <br /> 9234 East Valley Rd., Suite C <br /> Prescott Valley, AZ 86314 <br /> Tel: (602) 775-5191 Date of Evaluation: 12/11/92 <br /> 199 <br /> ' Appearance on this list is not to be construed as an endorsement by any regulatory agency nor is it any guarantee of the performance of the <br /> method or equipment. <br /> 42 7, 3 1 <br />
The URL can be used to link to this page
Your browser does not support the video tag.