Laserfiche WebLink
Alltech Petro Inc. an"annal <br /> 17759 Buttercup Circle, Sonora, CA 95370 <br /> Phone: 209-532-7320; Rax: 209-533-2650 <br /> California Contractor 623541 A-Haz <br /> Mike@,AlltechPetro.com <br /> MONITORING SYSTEM CERTIFICATION <br /> A. General Information <br /> Facility Name: Costco#658 Tracy Date of Testing/Servicing: September 29,2009 <br /> Facility Address: 3250 W Grant Line Rd.,Tracy CA 95304 <br /> Service Station Supervisor: Christine Hernandez Hut Phone: 209-834-1247 Warehouse Phone: 830-5343 <br /> LIA: San Joaquin Health; Inspector: Michelle Henry; LIA Phone: 468-3448; LIA Fax: 468-3433 <br /> Make/Model of Monitoring System: Veeder-Root TLS-350 <br /> B. Inventory of Equipment Tested/Certified: <br /> Tank ID: Regular 1 Tank Tank ID Regular 2 Tank <br /> ®In-Tank Gauging Probe Model:Mag 1 ®In-Tank Gauging Probe Model:Mag I <br /> ®Annular Space Sensor. Model:794380-301 ®Annular Space Sensor. Model 794380-301 <br /> ®Piping Sump Sensons) Model:793380-352 ®Piping Sump Sensors) Model: 793380-352 <br /> El Fill Sump Sensor(sl. Model:794380-352 ®Fill Sump Sensor(s). Model: 793380-352 <br /> ®Mechanical Line Leak Detector. Model:Red Jacket ®Mechanical Line Leak Detector. Model:Red Jacket <br /> ®Tank Overfill/High-Level Sensor. Model. V-R Audible ®Tank Overfill/High-Level Sensor. Model:V-R Audible <br /> ®Fillspill Bucket Tested: ®Pass ❑Fail ®Fillspill Bucket Tested. ®Pass ❑Fail <br /> ® Fire extinguishers inspected and tagged. ®OK ❑Not OK 0 Fire extinguishers inspected and tagged ®OK ❑Not OK <br /> Tank In Premium Tank: Tank ID:None <br /> 51 In-Tank Gauging Probe. Model.Mag 1 ❑In-Tank Gauging Probe. Model: <br /> ®Annular Space Sensor. Model: 794380-301 ❑Annular Space Sensor Model <br /> ®Piping Sump Sensors) Model 793380-352 ❑Piping Sump Sensors). Model: <br /> El Fill Sump Sensor(s). Model: 793380-352 ❑Fill Sump Sensor(s). Model. <br /> ®Mechanical Line Leak Detector. Model:Vaporless LD-2000 ❑ Line Leak Detector Model <br /> ®Tank Overfill/High-Level Sensor Model V-R Audible ❑Tank Overfill/High-Level Sensor Model <br /> ®Fillspill Bucket Tested: ®Pass ❑Fail ❑Fillspill Bucket Tested ❑Pass ❑Fail <br /> ® Fire extinguishers inspected and tagged: ®OK []Not OK ❑ Fire extinguishers inspected and tagged. ❑OK ❑Nol OK <br /> Dispenser ID: 1&2®Sump:®Dry []Water[]Product Dispenser to:3&4®Sump. ®Dry❑Water❑Product <br /> ®Dispenser Containment Sensor(s). Model: 794380-208 ®Dispenser Containment Sensor(s). Model. 794380-208 <br /> ElShearValvels) (Functional test) ®Shear Valve(s) (Functional test) <br /> ® Fire extinguisher inspected and tagged: ®OK ❑Not OK 0 Fire extinguisher inspected and tagged ®OK ❑Nol OK <br /> Dispenser ID:5&6®Sump. ®Dry❑Water❑Product Dispenser ID:7&8®Sump. ®Dry❑Water❑Product <br /> ®Dispenser Containment Sensor(s) Model 794380-208 ®Dispenser Containment Sensons). Model: 794380-208 <br /> ®Shear Valve(s) (Functional test) ®Shear Valve(s) (Functional test) <br /> ® Fire extinguisher inspected and tagged: ®OK ❑Nol OK ® Fire extinguisher inspected and tagged ®OK ❑Not OK <br /> Dispenser ID:9&10®Sump. ®Dry❑Water❑Product Dispenser ID: 11&12®Sump. ®Dry❑Water❑Product <br /> ®Dispenser Containment Sensors) Model:794380-208 ®Dispenser Containment Senors) Model 794380-208 <br /> ®Shear Valve(s) (Functional test) O Shear Valve(s) (Functional test) <br /> ® Fire extinguisher inspected and tagged ®OK ❑Not OK ® Fire extinguisher inspected and tagged ®OK ❑Not OK <br /> Dispenser ID: NONE❑Sump: ❑Dry❑Water❑Product Dispenser to: NONE❑Sump. ❑Dry❑Water❑Product <br /> ❑Dispenser Containment Sensor(s). Model. ❑Dispenser Containment Sensor(s). Model: <br /> ❑ShearValve(s) (Functional test) []ShearValve(s) (Functional test) <br /> ❑ Fire extinguisher inspected and tagged ❑OK ❑Not OK ❑ Fire extinguisher inspected and tagged ❑OK ❑Not OK <br /> C. Certification - 1 certify that the equipment identified in this document was inspecled/serviced in accordance with the manufaclumn' guidelines. <br /> .Attached to this Ucitif canon k a Plot Plan showing the lavonl of moniloriug equipment. For any equipment capable of generating such reports.I have <br /> itis.attached a copy or the report: [3 Syvtem set-up 0 Alarm hulory retort <br /> Technician: <br /> Date:9/29/09 <br /> Certification: <br /> Veeder-Root 636878,Level 2/3 ISD; Expires 08-13-2010 <br /> ICC UST Service Technician 9 8W5930-UT. Expires 06-14-2010 <br />