My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
COMPLIANCE INFO 2006-2012
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
COMPLIANCE INFO 2006-2012
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
2/25/2021 4:48:12 PM
Creation date
11/8/2018 10:21:49 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
COMPLIANCE INFO
FileName_PostFix
2006-2012
RECORD_ID
PR0518288
PE
2361
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS3\G\GRANT LINE\3250\PR0518288\COMPLIANCE INFO 2006-2012.PDF
QuestysFileName
COMPLIANCE INFO 2006-2012
QuestysRecordDate
7/5/2017 10:08:33 PM
QuestysRecordID
3482644
QuestysRecordType
12
QuestysStateID
1
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
418
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
■l�+7%`/ P.O.Box 4208 <br /> Alltechfetr - , Sonora CA 95370 <br /> Ca:623541 A-Haz <br /> Phone:209-532-7-7320 <br /> Compliance without Compromise Fax:209-533-2650 <br /> mailQalltechpetro.com <br /> www.alltechpetro.co m <br /> MONITORING SYSTEM CERTIFICATION <br /> A. General Information <br /> Facility Name: Costco#658 Tracy Date of Testing/Servicing: September 25, 2012 <br /> Facility Address: 3250 W Grant Line Rd.,Tracy CA 95304 <br /> Service Station Supervisor:Troy Dominici Hut Phone: 209-834-1247 Warehouse Phone: 830-5343 <br /> LIA: San Joaquin Health; Inspector:Thuy Tran; LIA Phone: 209-468-3440; LIA Fax: 209-468-8392 <br /> Make/Model of Monitoring System: Veeder-Root TLS-350 <br /> B. Inventory of Equipment Tested/Certified: <br /> Tank ID:87 A Tank Tank ID:87 B Tank <br /> Nln-Tank Gauging Probe. Model: Mag 1 Nln-Tank Gauging Probe. Model: Mag 1 <br /> ®Annular Space Sensor. Model:794380-301 ®Annular Space Sensor. Model: 794380-301 <br /> ®Piping Sump Sensor(s). Model: 793380-352 ®Piping Sump Sensor(s). Model: 793380-352 <br /> ®Fill Sump Sensor(s). Model: 794380-352 ®Fill Sump Sensor(s). Model: 793380-352 <br /> N Electronic Line Leak Detector. Model:VR PLLD ®Electronic Line Leak Detector. Model:VR PLLD <br /> ®Tank Overfill/High-Level Sensor. Model:V-R Audible ®Tank Overfill/High-Level Sensor. Model:V-R Audible <br /> N Fillspill Bucket Tested: ®Pass ❑Fail N Fillspill Bucket Tested: ®Pass []Fail <br /> ® Fire extinguishers inspected and to ed: NOK ❑Not OK N Fire extinguishers inspected and tagged: NOK []NotOK <br /> Tank ID: 91 Tank Tank ID: None <br /> N In-Tank Gauging Probe. Model: Mag 1 ❑In-Tank Gauging Probe. Model: <br /> ®Annular Space Sensor. Model:794380-301 ❑Annular Space Sensor. Model: <br /> ®Piping Sump Sensor(s). Model: 793380-352 ❑Piping Sump Sensor(s). Model: <br /> ®Fill Sump Sensor(s). Model: 793380-208 ❑Fill Sump Sensor(s). Model: <br /> ®Electronic Line Leak Detector. Model:VR PLLD ❑ Line Leak Detector. Model: <br /> ®Tank Overfill/High-Level Sensor. Model:V-R Audible ❑Tank Overfill/High-Level Sensor. Model: <br /> N Fillspill Bucket Tested: ®Pass [-]Fail ❑ Fillspill Bucket Tested: ❑Pass ❑Fail <br /> N Fire extinguishers inspected and tagged: NOK ❑Not OK ❑ Fire extinguishers inspected and tagged: ❑OK ❑Not OK <br /> Dispenser ID: 1&2 N Sump: NDry❑Water❑Product Dispenser ID: 3&4 N Sump: NDry❑Water❑Product <br /> N Dispenser Containment Sensor(s). Model:794380-208 ®Dispenser Containment Sensor(s). Model: 794380-208 <br /> ®Shear Valve(s) (Functional test) ®Shear Valve(s) (Functional test) <br /> N Fire extinguisher inspected and tagged: NOK ❑Not OK N Fire extinguisher inspected and to ed: NOK ❑Not OK <br /> Dispenser ID: 5&6 N Sump: NDry[-]water❑Product Dispenser ID: 7&8 N Sump: NDry❑Water❑Product <br /> N Dispenser Containment Sensor(s).Model: 794380-208 ®Dispenser Containment Sensor(s). Model: 794380-208 <br /> ®Shear Valve(s) (Functional test) ®Shear Valve(s) (Functional test) <br /> N Fire extinguisher inspected and tagged: NOK ❑Not OK N Fire extinguisher inspected and tagged: NOK ❑Not OK <br /> Dispenser ID: 9&10 N Sump: NDry❑Water❑Product Dispenser ID: 11&12 N Sump: NDry❑Water[]Product <br /> N Dispenser Containment Sensor(s).Model: 794380-208 ®Dispenser Containment Sensor(s). Model: 794380-208 <br /> ®Shear Valve(s) (Functional test) ®Shear Valve(s) (Functional test) <br /> N Fire extinguisher inspected and tagged: NOK ❑Not OK N Fire extinguisher inspected and tagged: NOK ❑Not OK <br /> Dispenser ID: NONE❑ Sump: []Dry[]water❑Product Dispenser ID: NONE❑ Sump: ❑Dry[]Water❑Product <br /> F-1 Dispenser Containment Sensor(s). Model: ❑Dispenser Containment Sensor(s). Model: <br /> ❑Shear Valve(s) (Functional test) ❑Shear Valve(s) (Functional test) <br /> ❑ Fire extinguisher inspected and tagged: ❑OK ❑Not OK ❑ Fire extinguisher inspected and tagged: ❑OK ❑Not OK <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is a Plot Plan showing the layout of monitoring equipment. For any equipment capable of <br /> generating such reports,I have also attached a copy of the report; ®System set-up ®Alarm history report <br /> Technician: .00 <br /> Date: 9/25/12 <br /> Certification: <br /> Veeder-Root 836877, Level 4 ISD; <br /> ICC UST Service Technician # 8152115-UT. <br />
The URL can be used to link to this page
Your browser does not support the video tag.