Laserfiche WebLink
C <br /> REEIVE <br /> P.O.eox 4208 <br /> Sonora CA 95370 <br /> Or O.,T Ca:623541 AAlitechlPetrZ= -Hoz <br /> 9 2u 1 07 Phone:209-532-7320 <br /> , <br /> Compliance without Compromise Fax:209-533-2650 <br /> ENVIRONMENTAL mail@alltechpetro.com <br /> ". -,r• hF www.ailtechpetro.com <br /> MONITORING SYSTEM CERTIF[C�AN <br /> A. General Information <br /> Facility Name: Costco #658 Tracy Date of Testing/Servicing: September 21, 2017 <br /> Facility Address: 3250 W Grant Line Rd., Tracy CA 95304 <br /> Service Station Supervisor: Tony Haggard Hut Phone: 209-834-1247 Warehouse Phone: 830-5343 <br /> LIA: San Joaquin Health; Inspector: John Alaniz; LIA Phone: 209-468-3440; email: jalanizl @sjcehd.com <br /> Make/Model of Monitoring System: Veeder-Root TLS-350 <br /> B. Inventory of Equipment Tested/Certified: <br /> Tank ID:Tank 1 Unleaded 87A Tank ID:Tank 2 Unleaded 87B <br /> N In-Tank Gauging Probe. Model: Mag 1 N In-Tank Gauging Probe. Model: Mag 1 <br /> ❑Annular Space Sensor. Model: 794380-301 ®Annular Space Sensor. Model: 794380-301 <br /> ❑Piping Sump Sensor(s). Model: 793380-352 ❑Piping Sump Sensor(s). Model: 793380-352 <br /> N Fill Sump Sensor(s). Model: 794380-352 N Fill Sump Sensor(s). Model: 793380-352 <br /> ❑Electronic Line Leak Detector. Model:VR PLLD ®Electronic Line Leak Detector. Model:VR PLLD <br /> ❑Tank Overfill/High-Level Sensor. Model:V-R Audible ❑Tank Overfill/High-Level Sensor. Model:V-R Audible <br /> N Fillspill Bucket Tested: ❑Pass ❑Fail N Fillspill Bucket Tested: Wass ❑Fail <br /> N Fire extinguishers inspected and tagged: NOK [:]NotOK N Fire extin uishers inspected and tagged: NOK ❑Not OK <br /> Tank ID:Tank 3 Unleaded 91 Tank ID:Tank 4 Additive Tank <br /> N In-Tank Gauging Probe. Model: Mag 1 Nin-Tank Gauging Probe. Model: Mag Plus <br /> ❑Annular Space Sensor. Model: 794380-301 ❑Annular Space Sensor. Model: 794380-303 <br /> ❑Piping Sump Sensor(s). Model: 793380-352 ®Piping/Fill Sump Sensor(s). Model: 793380-323 <br /> N Fill Sump Sensor(s). Model: 793380-208 N Fill Sump annular. Model: 794380-304 <br /> ®Electronic Line Leak Detector. Model:VR PLLD ®Mechanical Line Leak Detector. Model: Fe Petro <br /> ❑Tank Overfill/High-Level Sensor. Model:V-R Audible ®Tank Overfill/High-Level Sensor. Madel:V-R Audible <br /> N Fillspill Bucket Tested: ❑Pass ❑Fail N Fillspill Bucket Tested: ®Pass ❑Fail <br /> N Fire extinguishers inspected and to ed: NOK ❑Not OK N Fire extinguishers inspected and tagged: NOK ❑Not OK <br /> Dispenser ID: 1&2 N Sump: ❑Dry❑Water❑Product Dispenser ID: 3&4 N Sump: ®Dry❑Water ❑Product <br /> ®Dispenser Containment Sensor(s). Model: 794380-208 N Dispenser Containment Sensor(s). Model: 794380-208 <br /> NShear Valve(s) (Functional test) ❑Shear Valves) (Functional test) <br /> N Fire extinguisher inspected and tagged: NOK ❑Not OK N Fire extinguisher inspected and tagged: NOK ❑Not OK <br /> Dispenser ID: 5&6 N Sump: NDry❑Water❑Product Dispenser ID: 7&8 N Sump: ®Dry❑Water❑Product <br /> N Dispenser Containment Sensor(s). Model: 794380-208 N Dispenser Containment Sensor(s). Model:794380-208 <br /> NShear Valve(s) (Functional test) NShear Valve(s) (Functional test) <br /> N Fire extinguisher inspected and tagged: NOK ❑Not OK ® Fire extinguisher inspected and tagged: NOK ❑Not OK <br /> Dispenser ID: 9&10 N Sump: NDry❑Water El Product Dispenser ID: 11&12 N Sump: ®Dry❑Water❑Product <br /> ❑Dispenser Containment Sensor(s). Model: 794380-208 ®Dispenser Containment Sensor(s). Model: 794380-208 <br /> NShear Valves) (Functional test) NShear Valve(s) (Functional test) <br /> N Fire extinguisher inspected and tagged: NOK ❑Not OK N Fire extinguisher inspected and tagged: NOK ❑Not OK <br /> Dispenser ID: Vent Box N Sump: ®Dry❑Water ❑Product Dispenser ID: ❑ Sump: ❑Dry ❑Water❑Product <br /> N Dispenser Containment Sensor(s). Model: 793380-323 ❑Dispenser Containment Sensor(s). Model: <br /> ® UDC Annular Space Sensor. Model: 794380-304 ❑Shear Valves) (Functional test) <br /> ® Fire extinguisher inspected and tagged: NOK ❑Nat OK ❑ Fire extinguisher inspected and tagged: ❑OK ❑Not OK <br /> C. Certification - I certify that the equipment identified in this document was inspected/serviced in accordance with the manufacturers' <br /> guidelines. Attached to this Certification is a Plot Plan showing the layout of monitoring equipment. For any equipment capable of <br /> generating such reports, I have also attached a copy of the report; ® System set-up ®Alarm history report <br /> Technician: <br /> Date: 09/21/17 <br /> Certification: <br /> Veeder-Root 1336878, Level 4 ISD; <br /> iCC UST Service Technician # 8146912-UT. <br />