My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2013
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
INSTALL_2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/31/2022 3:09:55 PM
Creation date
11/8/2018 10:21:55 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2013
RECORD_ID
PR0518288
PE
2361
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS3\G\GRANT LINE\3250\PR0518288\INSTALL 2013.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
249
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
LUBRIZOLS 9888 <br /> 5 1 FireFighting Measures <br /> Flash Point 32°C,89.6°F PMCC(Typical) <br /> Extinguishing Media CO2,dry chemical,or foam.Water can be used to cool and protect exposed material. <br /> Firefighting Procedures Recommend wearing self-contained breathing appamem.Water may cause splattering. <br /> Unusual Fire&Explosion Hazards Toxic fumes,gases in vapors may evolve on bunting.Vapors may be heavier than air and may travel along the ground to a <br /> distant ignition source and flash hack.Container may rapture on heating.See section 10 for additional information. <br /> 6 1 Accidental Release Measures <br /> Spill Procedures May form explosive mixtures with aa.Immediately evacuate all personnel from danger area.Personal Protective Equipment <br /> must be wom,see Personal Protection Section for PPE recommendations.Take precautions to avoid release to the <br /> environment Eliminate all sources of heat,sparks pilot lights,static electricity and open flames.Ventilate spill area.Prevent <br /> entry into sewers and waterways,dispose of in accordance with all federal,state and local environmental regulation.Pick up <br /> free liquid for recycle and/or disposal if can be accomplished safely with explosion proof equipment Residual liquid can be <br /> absorbed on inert material.Check under Transportation and Labeling(DOT/CERCLA)and Other Regulatory Information <br /> Section(SARA)for hazardous substances to determine regulatory reporting requirements for spills. <br /> 7 1 Handling and Storage <br /> Pumping Temperature Not determined <br /> Maximum Handling Temperature Not determined. <br /> Handling Procedures Keep away from ignition sources such as heat,sparks and open Flame.No smoking.Keep containers closed when not in <br /> use.Do not discharge into drains or the environment,dispose to an authorized waste collection point.Use appropriate <br /> containment to avoid environmental contamination.Avoid breathing dust,fame,gas,mist,vapors or spray.Ground/bond <br /> container and receiving equipment.Use explosion-proof equipment.Take precautionary measures against static discharge. <br /> Use only non-sparking tools.Use only outdoors or in a well-ventilated area Wash thoroughly after handling.Launder <br /> contaminated clothing before reuse.Empty containers retain material residue.Do not cut,weld,braze,solder,drill,grind or <br /> expose containers to hear,flame,spark or other sources of ignition.Dispose of packaging or containers in accordance with <br /> local,regional,national and international regulations. <br /> Maximum Storage Temperature Not detemtined <br /> Storage Procedures Do not store near potential sources of ignition.Isolated outside storage is preferred.Inside storage area should be in a <br /> flammable liquids cabinet or storage area.Take precautions to avoid release to the environment.Store in a well-ventilated <br /> place.Keep cool.Keep container tightly closed.See section 10 for incompatible materials. <br /> Maximum Loading Temperature Not determined. <br /> 8 1 Exposure Controls/Personal Protection <br /> Exposure Limits <br /> tToh7Exposure Guidelines <br /> �- �--. ACGHI Other <br /> TWA STEL TWA STEL j TWA STEL <br /> 0 ppm N/E 100 ppm 150 ppm N/E N/E <br /> 0 ppm N/E 100ppm 125 ppm N/E N/E <br /> N/E N/E N/E N/E 100 m(1) N/E <br /> 0 ppm N/E 10ppm(s) 15 ppm N/E0 ppm 300 ppm(c) 20 ppm NB N/E N/E <br /> (s)-Skin exposure <br /> (p)-Proposed limit <br /> (c)-Ceiling exposure <br /> p)-Recommended exposure limit <br /> (u)-Supplier—ended exposure limit <br /> (N/E)-None established <br /> Other Exposure Limits None known. <br /> Engineering Controls Use local exhaust ventilation in control mists or vapors.Additional ventilation or exhaust may be required to maintain air <br /> concentrations below recmmnended exposure limits.Use explosion proof equipment. <br /> Gloves Procedures Viton.Teflon.Polyvinyl alcohol.Note:polyvinyl alcohol gloves are water soluble and should not be used when them is <br /> potential for water contact. <br /> Eye Protection Safety glasses.Ifpotential for splash or mist exists,wear chemical goggles or fsceshield <br /> Respiratory Protection Use NIOSH/MSHA approved full face respirator with a combination organic vapor and high efficiency filter cartridge if the <br /> recommended exposure limit is exceeded Use self-contained breathing apparatus for entry into confined space,for other <br /> poorly ventilated areas and for large spill clean-up sites.Consult with an industrial hygienist to determine the appropriate <br /> respiratory protection for your specific use of this material.A respiratory protection program compliant with all applicable <br /> regulations most be followed whenever workplace conditions require the use of a respirator. <br /> Clothing Recommendation Gloves,coveralls,apron,boots as necessary to minimize contact.Wear a chemically protective apron when contact with <br /> material may occur Do not wear rings,watches or similar apparel that could entrap the material and cause a skin reaction. <br /> Launder contaminated clothing before reuse. <br /> Page 2/6 <br />
The URL can be used to link to this page
Your browser does not support the video tag.