My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2013
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
G
>
GRANT LINE
>
3250
>
2300 - Underground Storage Tank Program
>
PR0518288
>
INSTALL_2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
5/31/2022 3:09:55 PM
Creation date
11/8/2018 10:21:55 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2013
RECORD_ID
PR0518288
PE
2361
FACILITY_ID
FA0013810
FACILITY_NAME
COSTCO WHOLESALE #658
STREET_NUMBER
3250
Direction
W
STREET_NAME
GRANT LINE
STREET_TYPE
RD
City
TRACY
Zip
95377
CURRENT_STATUS
01
SITE_LOCATION
3250 W GRANT LINE RD
P_LOCATION
03
QC Status
Approved
Scanner
WNg
Supplemental fields
FilePath
\MIGRATIONS3\G\GRANT LINE\3250\PR0518288\INSTALL 2013.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
249
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
� Items#35 <br /> • <br /> • • _ P • <br /> • Alternative • <br /> Certified performance for inventory <br /> control and in-tank leak detection in <br /> fuel blends up to 100% alcohol <br /> Veeder-Root offers two types of The TLS-300 and TLS-350(R) equipped The 0.2 GPH Mag Probe for Alternative <br /> Magnetostrictive Probes for Alternative with CSLD use the 0.1 GPH Mag Probe to Fluids has also been third-party tested and <br /> Fluids to provide highly accurate, trouble- continuously monitor fuel height and tem- certified to exceed U.S.EPA. standards for <br /> free in-tank leak detection and inventory perature information to detect idle times in 0.2 GPH automatic tank gauging. (See the <br /> control in fluids of up to 100%alcohol.The the tank. During each idle time, data summary of leak test performance on back <br /> Magnetostrictive Probe for Alternative collected forms a highly accurate leak or call us for a copy of the complete test <br /> Fluids with water detection is ideal for fuel detection database. Sophisticated statistical results.) <br /> blends with less than 20% alcohol. The analysis techniques in CSLD constantly <br /> Magnetostrictive Probe for Alternative evaluate the database to discard invalid data Approved for Aboveground Tank <br /> Fluids without water detection has been and perform leak tests based on only high- Applications <br /> developed for fluids up to 100% alcohol. quality information in the current database. Viceder-Root Magnetostrictive Probes are <br /> In fact, a new leak test is performed every approved for use in aboveground storage <br /> Series 8463 0.1 GPH Mag Probe time new data from an idle period is added, tanks to monitor fuel inventory. An AST <br /> for Alternative Fluids installation Kit (Form Number 312020- <br /> The 0.1 GPH Mag Probe for Alternative Series 8463 0.2 GPH Mag Probe 984) is required for these applications and <br /> Fluids has been third-party tested and for Alternative Fluids is available from Veeder-Root, Customer <br /> certified to perform far better than the U.S. The 0.2 GPH Mag Probe for Alternative Service 800-873-3313 or your authorized <br /> E.PA. standards for both 0.1 GPH volu- Fluids provides the same reliable inventory Veeder-Root distributor. <br /> metric tank tightness testing and 0.2 GPH control features and fluid compatibility as <br /> automatic tank gauging. (See the summary the 0.1 GPH Mag Probe for Alterative <br /> of leak test performance on back or call us Fluids,but offers 0.2 GPH leak detection at <br /> for a copy of the complete test results.) a lower cost. anngnaweHws <br /> ��•a•a•:,01 err <br /> e 0,2G HUa59ns <br /> 0.1 GPH Mag Probe and CSLD — <br /> Leak detection without shutting <br /> down your tanks! <br /> CSLD, Continuous Statistical Leak <br /> Detection,is an advanced tank testing tech- Features & BenefYts <br /> nology that makes full use of the TLS-300 . Non-corrosive,stainless steel tubing 0.1 GPH Mag Probe for Alterative <br /> and TLS-350(R)s in-tank monitoring capa- for long-life monitoring in fuels up to Fluids is compatible with TIS-300 <br /> bilities. CSLD eliminates the need for tank 100%alcohol and TLS-350R with CSLD for <br /> shutdown to perform a leak test—no lost continuous statistical leak detection <br /> business,no lost operating time! • Highly accurate Magnetostrictive <br /> measurement technology 0.2 GPH Mag Probe for Alternative <br /> Fluids is third-patty certified to <br /> • Fast accurate leak tests exceed U.S. E.PA.performance <br /> standards for 0.2 GPH Automatic <br /> • 0.1 GPH Mag Probe for Alternative Tank Gauging <br /> Fluids is third-party certified to <br /> exceed U.S.ERA.performance 2",3" and 4"Float Kits available <br /> standards for 0.1 GPH Volumetric <br /> Tank Tightness Testing <br /> �� VEEDER-ROOT <br />
The URL can be used to link to this page
Your browser does not support the video tag.