My WebLink
|
Help
|
About
|
Sign Out
Home
Browse
Search
INSTALL_2013
Environmental Health - Public
>
EHD Program Facility Records by Street Name
>
H
>
HAMMER
>
1630
>
2300 - Underground Storage Tank Program
>
PR0518624
>
INSTALL_2013
Metadata
Thumbnails
Annotations
Entry Properties
Last modified
3/11/2021 1:02:11 PM
Creation date
11/8/2018 10:22:05 AM
Metadata
Fields
Template:
EHD - Public
ProgramCode
2300 - Underground Storage Tank Program
File Section
INSTALL
FileName_PostFix
2013
RECORD_ID
PR0518624
PE
2371
FACILITY_ID
FA0024496
FACILITY_NAME
Costco Wholesale #38 (Gas Station)
STREET_NUMBER
1630
Direction
E
STREET_NAME
HAMMER
STREET_TYPE
Ln
City
Stockton
Zip
95210
APN
09428011
CURRENT_STATUS
01
SITE_LOCATION
1630 E Hammer Ln
QC Status
Approved
Supplemental fields
FilePath
\MIGRATIONS3\H\HAMMER\1630\PR0518624\INSTALL PLAN 2013.PDF
Tags
EHD - Public
Jump to thumbnail
< previous set
next set >
There are no annotations on this page.
Document management portal powered by Laserfiche WebLink 9 © 1998-2015
Laserfiche.
All rights reserved.
/
269
PDF
Print
Pages to print
Enter page numbers and/or page ranges separated by commas. For example, 1,3,5-12.
After downloading, print the document using a PDF reader (e.g. Adobe Reader).
View images
View plain text
BCE#10199 <br /> F. SYSTEM PIPING CONTINUED: <br /> Check CC <br /> Box gecdtion <br /> HSC Piping compatible with material intended to be stored. <br /> ❑X 25290.1 c 1 <br /> 25290.2 c 1 <br /> 23 CCR <br /> 2631(b) Design and construction of piping approved by independent testing organization e. . UL). <br /> IX Piping, including vent lines,sloped toward tanks with minimum 1/4 inch sloe per 1 foot of run. <br /> HSC <br /> ❑X 25290 1 ckj (j) Vapor recovery,fill riser, and vent line piping are secondarily contained. <br /> G. OVERSPILL/ OVERFILL PREVENTION: <br /> Check C <br /> Box Section <br /> 23 CCR Overspill containment having minimum capacity of 5 gallons provided at each tank fill location. <br /> IX 2635(b) Manufacturer OPW Model <br /> Approved overfill prevention device provided at each tank fill location. <br /> Choose One of the following methods: <br /> No X Alert the transfer operator when the tank is 90 percent full by restricting the flow into the tank or <br /> triggering an audible visual alarm <br /> ❑ Restrict delivery of flow to the tank at least 30 minutes before the tank overfills, provided the <br /> 23 CCR restriction occurs when the tank is filled to no more than 95 percent capacity;and activate an <br /> EX 2635(b)(2) audible alarm at least five minutes before the tank overfills <br /> ❑ Provide positive shut-off flow to the tank when the tank is filled to no more than 95 percent of <br /> capacity. <br /> ❑ Provide positive shut-off of flow to the tank so that none of the fittings located on the top of the <br /> tank are exposed to product due to overfilling. <br /> Manufacturer Veeder-Root Model Overfill Alarm#790091-002;with Level Gauge#846391- 1 <br /> H. CORROSION PROTECTION: <br /> Check Code <br /> Box Section <br /> IX Fiberglass reinforced plastic(FRP) <br /> Piping corrosion protection: ❑ Steel with cathodic protection or impressed current <br /> $ 23 CCR ❑ Steel isolated from contact with backfill <br /> 2636(b) <br /> lXFRP or equivalent non-metallic exterior coatings or coverings <br /> Tank corrosion protection: ❑ Sacrificial Anode <br /> [y� 25 5(aj(2) ❑ Steel tank with field installed cathodic protection or impressed <br /> current <br /> Tie-downs,when used,constructed of non-corrosive material or coated steel. (Tar Coat Epoxy) <br /> Revised 8/1/11 7 <br />
The URL can be used to link to this page
Your browser does not support the video tag.